User’s Guide
HRP 220
-
29
-
HS
Maintenance
10
10.4.2
Emptying
1.
Disconnect the compressed air.
The top frame will lower slowly.
2.
Remove the left-hand frame plate on the front of the machine
3.
Remove the 2 screws in the front of the Timer unit, and 1 in the
back of the timer unit.
4.
Lift the back of the Timer unit a bit, so that you can put a
container underneath the Glass Holder (if necessary, remove
some connectors to make room as explained in section
12.3
. These are not
interchangeable, and so they cannot be put in the wrong socket. Before performing
this action,
make sure the main power switch is off!)
5.
Slowly open the nipple. All the water will then run out of the glass holder, in the
container underneath.
6.
Close the drain nipple by hand.
7.
Reposition the Timer unit, and all the connectors that may have been removed earlier.
Screw the timer unit back into place.
8.
Screw the left-hand frame plate on the front of the machine, back in position.
9.
Switch the machine on again as described in Section
7
.
Drain nipple
Glass holder