DOCUMENT
943200-11 ETM RECORDER
Control
SC1
INSTALLATION MANUAL
Revision
–
M943200-11
Page: 11 of 17
SHADIN AVIONICS
www.shadin.com
Customer Service: (952) 836-2269
5.1.3
ETM SETUP
The following steps describe how to configure the ETM for use with the ETM Recorder.
Display
The display of the ETM contains two lines, 12 characters per line.
Enter/Test Button
Enter individual character in a line of data.
Increment/Decrement Switch
Steps to the next available character position in a data entry field
or steps to the next field
Rotary Select Switch
Select one of the four files from which to display pages:
Miscellaneous, Airframe, Left Engine, and Right Engine.
Up/Down Switch
Scrolls through pages
Reset Button
Erases data saved in various exceedance files in ETM memory.
Scroll through the character sets for entering data. Character sets
are as follows:
Character set 1 contains the letters A through Z
Character set 2 contains the numbers 0 through 9
Character set 3 contains the characters [ ‘ _ ^ ] and \
Character set 4 contains / . -
, + * ) ( ‘ & % $ # “ ! and a space
Start/Stop Switch
Start position begins Diagnostic Mode from Data Entry Mode.
Stop position exits Diagnostic and Data Entry Mode.
Record Button
Enters selections into ETM memory