background image

GB 

 

SGM

 

 

Idea  Spot  700   

 

XM473-V1.0-NR 

11

 

Control Board 

The Control Board offers several features: you can simply set the starting address, switch on and off the 
lamp, run the pre-programmed program or make a reset. 
The main menu is accessed by pressing the 

Mode/esc

-button until the display starts flashing. Browse 

through the menu by pressing the 

Up

-button or 

Down

-button. Press the 

Enter

-button in order to select 

the desired menu. You can change the selection by pressing the 

Up

-button or 

Down

-button. Confirm every 

selection by pressing the 

Enter

-button. You can leave every mode by pressing the 

Mode/esc

-button. The 

functions provided are described in the following sections. 

 
To access the display menu via the internal battery, press the UP or DOWN button. The display 
will automatically switch off about 10 seconds after the last actuation of the buttons. 

 
Default settings shaded 

F

u

n

c

ti

o

n

 

M

o

d

e

 

Set Dmx Address 

Value Display 

Set To Slave 

Auto Program 

Music Control 

A001~AXXX 

PAN…… 

Slave1,Slave2,Slave3 

Master / Alone 

Master / Alone 

DMX address setting 

DMX value display 

Slave setting 

Auto program 

Music control 

Time Information 

Current Time 

Total Life Hours 

Last Run Hours 

Lamp Hours 

Lamp Off Time 

Timer Password 

Clear Last Run 

L-Timer Password 

Clear Lamp Time 

XXXX(Hours) 

XXXX(Hours) 

XXXX(Hours) 

XXXX(Hours) 

XXXX(Minute) 

Password=XXX 

ON/OFF 

Password=XXX 

ON/OFF 

Power on running time 

Fixture running time 

Fixture Last times clear 

Lamp running time 

Lamp off time 

Timer Password 

038

 

Clear Fixture Last time 

Lamp Password Code=”038” 

Clear lamp time 

Temperature Info 

Head Temperature 

XXX°C/°F 

Temperature in the head 

In

fo

rm

a

ti

o

n

 

Software Version 

Ver1.0……

 

Software version of each IC 

L

a

m

p

 C

o

n

tr

o

Lamp On or Off 

Automatic La-On 

Lamp On Via DMX 

Lamp Off Via DMX 

Lamp On at Temp. 

Lamp Off at Temp. 

ON/OFF 

ON/OFF 

ON/OFF 

ON/OFF 

20~79°C,45°C /68~174°F 113°F 

80~139°C, 130°C /176~282°F, 266°F 

Lamp on/off 

Lamp on/off when Power on 

Lamp on via DMX 

Lamp off via DMX 

Lamp restart at temp. 

Lamp off at temp. 

Status Settings 

Address via DMX 

No DMX Status 

Pan Reverse 

Tilt Reverse 

Pan Degree 

Feedback 

Movement Speed 

Mic Sensitivity 

Hibernation

 

ON/OFF 

Close/Hold/Auto/Music 

ON/OFF 

ON/OFF 

630/540 

ON/OFF 

Speed 1~ 4 

0~99% 

0FF/1~99M

15M

 

Add. via DMX 

Auto run if no DMX 

Pan Reverse movement 

Tilt Reverse movement 

Pan Degree Select 

Movement Feedback switch 

Movement Mode Select 

Sensitivity of Mic. 

Stand by mode

 

Service Setting 

Service Password 

Fan Voltage   

Gobo Speed 

Password=XXX 

High/Low 

Quick/Slow 

Service Code“=050” 

Fan Voltage Select   

Gobo Change Speed 

Fans Control 

Auto Fans Speed 

High Fans Speed 

Low Fans Speed 

Fans Speed Mode Select 

P

e

rs

o

n

a

li

ty

 

Display Setting 

Shutoff Time 

02~59m 05m 

Display shutoff time 

Summary of Contents for IDEA SPOT 700

Page 1: ...0 0 1 L E R L A U N A M S R E S U GB I D F E P M O V I N G H E A D S IDEA SPOT 700...

Page 2: ...enst SGM beh lt sich das Recht vor Verbesserungen an den Produkten vorzunehmen und deshalb empfehlen wir die Bedienungsanleitung dem Produkt stets beizulegen und die Seriennummer auf der letzten Seite...

Page 3: ...hod via clamp DMX 512 control connection Control Board FUNCTION MODE DMX Address Setting Display the DMX 512 value of each channel Slave Setting Auto Program Music control INFORMATION Time information...

Page 4: ...solution For smooth and precise resolution Pan 540 630 optional Tilt 265 movement High speed of pan tilt movement speed of pan tilt movement is adjustable Scan position memory auto reposition after un...

Page 5: ...ective lens 2 LCD Display 3 Mode Esc button 4 Up button 5 Down button 6 Enter button 7 Microphone 8 Wireless DMX antenna 9 Wireless indicator 10 Lamp system 11 Yoke 12 Carrying handle 13 DMX output so...

Page 6: ...than stated at the end of this manual Make sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always...

Page 7: ...correctly If you use the quick lock cam in hanging up the fixture please make sure the 4 quick lock fasteners turned in the quick lock holes correctly Operate the device only after having familiarize...

Page 8: ...insert the lamp Gently slide the lamp and its lamp holder back into place and fasten the 4 screws 4 On the access plate there are 3 small screws marked 1 2 and 3 which are used to adjust the lamp hold...

Page 9: ...ve to be approved by a skilled person once a year The lighting should be put in a relatively broad space Ensure there is no barrier in the range of 50cm around the lighting CAUTION Before taking into...

Page 10: ...ga holder Pull the safety rope through the holes on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw DMX 512 cont...

Page 11: ...channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct n...

Page 12: ...less system 1 Connect the transmitter with the DMX controller 2 To make the fixture installed with wireless receiver log in to the transmitter a Initially the indicator on the receiver fixture should...

Page 13: ...d Clear Lamp Time XXXX Hours XXXX Hours XXXX Hours XXXX Hours XXXX Minute Password XXX ON OFF Password XXX ON OFF Power on running time Fixture running time Fixture Last times clear Lamp running time...

Page 14: ...Adjust Calibrate Values Password Color wheel Password XXX Color wheel XXX Calbrate and adjust the effects to standard right position Password 050 User Mode Standard Mode Basic Mode Extended Mode User...

Page 15: ...RMATION Time information Current Time With this function you can display the temporary running time of the device from the last power on The display shows XXXX XXXX stands for the number of hours The...

Page 16: ...e lamp is full intensity Lamp on off With this function you can switch the lamp on or off via the Control Board Select Lamp on off by turning the encoder Press the encoder the display shows ON or OFF...

Page 17: ...nel 3 to 57 If you want to set the starting address to 420 set channel 1 to 7 channel 2 to 8 and channel 3 to 164 256 164 420 Wait for approx 20 seconds and the unit will carry out a reset After that...

Page 18: ...h this function you can adjust the lamp more easily All effects will be canceled the shutter opens and the dimmer intensity will be set to 100 With the individual functions you can focus the light on...

Page 19: ...ode by turning the encoder Press the Enter button to confirm Select Auto Program by turning the encoder Press the Enter button to confirm Turn the encoder to select Master or Alone The selection Alone...

Page 20: ...der to select the desired scene numbers You can program a maximum number of 250 scenes Press the Enter button to confirm Press the Mode Esc button in order to return to the main menu Example Program 2...

Page 21: ...l wheel changing 5 3 5 246 255 no function Color Wheel 0 13 Open white 14 27 Color 1 28 41 Color 2 42 55 Color 3 56 69 Color 4 70 83 Color 5 84 97 Color 6 98 111 Color 7 112 127 Color 8 128 189 Forwar...

Page 22: ...slow 190 193 No rotation 11 9 15 194 255 Backwards gobo rotation from slow to fast Rotating gobo indexing Fine 1 16 0 255 Fine indexing Rotating gobos cont rotation 2 0 9 Open 10 19 Rot gobo 1 20 29 R...

Page 23: ...14 12 20 248 255 Macro 16 Focus 15 13 21 0 255 Continuous adjustment from near to far Focus Fine 22 0 255 Continuous adjustment Fine Motorized Zoom 16 14 23 0 255 Zoom adjustment from small to big Mot...

Page 24: ...to slow 224 254 Pulse closing slow to fast 21 19 31 255 Max Frost Speed Of CMY Colour macro Speed 22 20 32 0 255 Speed Max Min Colour macros CMY and colour wheel 0 7 OFF 8 15 Macro1 16 23 Macro2 24 31...

Page 25: ...eset 85 87 Scan motor reset 88 90 Colors motor reset 91 93 Gobo motor reset 94 96 Shutter Dimmer motor reset 97 99 Other motor reset 100 119 Internal program 1 secne1 8 of EEPROM 120 139 Internal prog...

Page 26: ...This message will appear after the reset of the fixture if the magnetic indexing circuit malfunction sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main P...

Page 27: ...ons and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power supply cables must not sh...

Page 28: ......

Page 29: ......

Page 30: ...0 0 1 L E R L A U N A M S R E S U 3 7 4 M X MADE IN PRC...