GB
SGM
Idea Spot 700
XM473-V1.0-NR
15
Please note that the outside temperature should not exceed 45° C.
When the temperature around the lamp is higher than the preset value continuously up to 5
minutes, the lamp will be shut off automatically.
If the lamp be shut off automatically due to over heat, it can not be striked again automatically,
it must be turned on again by manually.
PERSONALITY
Status Settings
Address Via DMX
With this function, you can adjust the desired DMX-address via an external controller.
Select
“Address via DMX”
by turning the encoder.
Press the encoder, the display shows “ON” or “OFF”.
Turn the encoder to select “ON” if you wish to enable this function or “OFF” if you don’t.
Press the encoder to confirm.
Press the Mode/Esc-button in order to return to the main menu.
On the controller, set the DMX-value of channel 1 to "7".
Set the DMX-value of channel 2 to "7"or "8". When set to "7" you can adjust the starting address
between 1 and 255. When set to "8" you can adjust the starting address between 256 and 511.
Set the DMX-value of channel 3 to the desired starting address. If you want to set the starting address
to 57, set channel 1 to "7", channel 2 to "7" and channel 3 to "57". If you want to set the starting
address to 420,set channel 1 to "7", channel 2 to "8" and channel 3 to "164" (256+164=420).
Wait for approx. 20 seconds and the unit will carry out a reset. After that, the new starting address is
set.
Hold If No DMX
With this function, when the drive is not DMX signal, it runs automatism, close, hold and music, the default
is hold.
Pan Reverse
With this function you can reverse the Pan-movement.
Tilt Reverse
With this function you can reverse the Tilt-movement.
Pan Degree
With this function, you can select pan degree for 630 or 540.
Feedback
With this function, you can feedback switch of pan movement or tilt movement.
Movement Speed
With this function, you can select scan mode from 1 to 4.
Mic Sensitivity
With this function, the default is 70%, you can select the desired microphone sensitivity from 0 % to 99 %.
Hibernation
Stand by mode - 0FF/1~99M
,
15M
Service Setting
Service Password
With this function, you can set the service password.
Fan Voltage
With this function, you can select fan voltage for high or low, the default is High.
Attention: The model is not recommended when ambient temperature is higher than 15 Celsius
degree.
Gobo speed
With this function, you can select GOBO speed for quick or slow, the default is Quick.
Fans Control
With this function, you can set the speed of the running fans. The selections have Auto
、
high and low.