background image

 

 

GB 

XM368-V1.2 -B 

 

  Idea Par Led Zoom RGB

 

Make sure the power cord is never crimped or damaged by sharp edges. If this would be the case, 
replacement of the cable must be done by an authorized dealer. 
 
Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the power 
cord by the plug. Never pull out the plug by tugging the power cord. 
 
During initial start-up some smoke or smell may arise. This is a normal process and does not necessarily 
mean that the device is defective, it should decrease gradually. 
 
Please don't project the beam onto combustible substances. 
 
Fixtures cannot be installed on combustible substances, keep more than 30cm distance with wall for smooth 
air flow, so there should be no shelter for fans and ventilation for heat radiation. 
 
If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the 
manufacturer or his service agent or a similar qualified person in order to avoid a hazard. 

 

CAUTION! 

 

Never touch device during operation! The housing may heat up 

 

Never look directly into the light source, as sensitive persons may suffer an 
epileptic shock. 

 

Please be aware that damages caused by manual modifications to the device are not subject to warranty. 
Keep away from children and non-professionals. 
 

GENERAL GUIDELINES 

This device is a lighting effect for professional use on stages, in discotheques, theatres, etc. 
This fixture is only allowed to be operated with the max alternating current which stated in the technical 
specifications in the last page of this manual, the device was designed for indoor use only. 
Lighting effects are not designed for permanent operation. Consistent operation breaks may ensure that the 
device will serve you for a long time without defects. Do not shake the device. 
Avoid brute force when installing or operating the device. 
The device shall only be used complete with its protective shield. 
While choosing the installation-spot, please make sure that the device is not exposed to extreme heat, 
moisture or dust. The minimum distance between light-output from the projector and the illuminated 
surface must be more than 0.1 meter. 
 
Operate the device only after having familiarized with its functions. Do not permit operation by persons not 
qualified for operating the device. Most damages are the result of unprofessional operation. 
 
Please use the original packaging if the device is to be transported. 
For safety reasons, please be aware that all modifications on the device are forbidden. 
 
If this device will be operated in any way different to the one described in this manual, the product may 
suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 
short-circuit, burns, electric shock, lamp explosion, crash, etc. 
 

Summary of Contents for Idea Par LED Zoom RGB

Page 1: ...ONS 3 GENERAL GUIDELINES 4 INSTALLATION INSTRUCTIONS 5 Mounting the device 5 Overhead rigging 6 DMX 512 control connection Errore Il segnalibro non definito Control Board 8 Main functions 9 INSTRUCTIO...

Page 2: ...ser manual from the Internet INTRODUCTION Thank you for having chosen this professional LED lighting You will see you have acquired a powerful and versatile device Unpack the device Inside the box you...

Page 3: ...aler will not accept liability for any resulting defects or problems If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising cond...

Page 4: ...professionals GENERAL GUIDELINES This device is a lighting effect for professional use on stages in discotheques theatres etc This fixture is only allowed to be operated with the max alternating curr...

Page 5: ...ne technical installations are approved by an expert before taking the device into operation for the first time These installations have to be approved by a skilled person once a year CAUTION Before t...

Page 6: ...control connection The product has a DMX 512 input fitted with standard 5 pin XLR connectors Screened cables in compliance with EIA RS 485 specifications and the following characteristics must be use...

Page 7: ...MX starting address when using a DMX signal so that the correct fixture responds to the correct control signals This digital starting address is the channel number from which the fixture starts to lis...

Page 8: ...sensitivity FAIL OFF HOLD AUTO SOUN No DMX Status REST Reset DFSE ON OFF Restore factory settings POHO ON OFF Power on to preserve the MANL settings 1 SET VER V 1 0 V 9 9 Software version 2 MANL RED...

Page 9: ...this function you can define the device as slave 1 Select SLAV by pressing UP or DOWN button 2 Press ENTER the display shows ON or OFF 3 Press UP to select ON if you wish to enable this function or p...

Page 10: ...rm the display shows D 00 In this setting the DMX adjustment of every channel will be displayed 3 Press UP or DOWN button in order to select the desired channel If you select D 12 the display will onl...

Page 11: ...umber from 0 to 99 3 Press ENTER to confirm or Press MENU to return to the main menu Automatic Run by no DMX With this function you can automatic run the device by no DMX 1 Select FAIL by pressing UP...

Page 12: ...Manual adjust intensity 1 Select MANL by pressing UP or DOWN button 2 Press ENTER the display shows RED GREN BLUE MACO PROG STRB DIMM ZOOM 3 Press UP or DOWN button to select RED GREN BLUE MACO PROG...

Page 13: ...ion you can edit the program to be called up in Run a Editing via the Control Board 1 Select SC01 by pressing UP or DOWN button 2 Press ENTER the display shows SCXX X stands for the scene no to be edi...

Page 14: ...ws FADE Adjust fade speed 6 Press ENTER the display to be adjust fade speed 7 Select CEDT by pressing UP or DOWN button 8 Press ENTER the display shows OFF 9 Press UP or DOWN button the display shows...

Page 15: ...macro 6 48 55 Color macro 7 56 63 Color macro 8 64 71 Color macro 9 72 79 Color macro 10 80 87 Color macro 11 88 95 Color macro 12 96 103 Color macro 13 104 111 Color macro 14 112 119 Color macro 15...

Page 16: ...ram 7 5 221 255 Gradient effect Shutter strobe 0 31 Led trun off 32 63 Led turn on 64 95 Strobe effect slow to fast 96 127 Led turn on 128 159 Pulse effect in sequences 160 191 Led turn on 192 223 Ran...

Page 17: ...s on the housing fixations and installation spots ceiling suspension trussing 3 Mechanically moved parts must not show any traces of wearing and must not rotate with unbalances 4 The electric power su...

Page 18: ...sumption max 120 W Packing dimensions 40 x 30 x 48 CM Flight case dimensions 79x76 5x60 cm Net weight 7 KGS Gross weight 10KGS carton packing 75 5 KGS flight case packing 6pcs Remark errors and omissi...