In a stand-alone operation mode the fixture is not running connected to a control device, but it is pre-programmed with a series of up 

to 24 scenes, playing continuously in a loop. This program can be set up to run by default whenever the fixture is powered on. 

Manual control / Internal sequence editor

The editor option offers the ability to adjust all DMX parameters of the fixture. Each scene has its own DMX settings with the possibility 

to define a fade-in time for the transition from the previous scene, and a 

wait (static) time, each with a fade time up to 4000 seconds and a wait 

time up to 4000 seconds.
The 24 scenes can be preset directly from the control menu of the fixture 

by using the editor.  
Locate the editor by pressing 'OK' in the menu and selecting 'MANUAL'.

The following option will be available: 

•  Editor

•  Run Program

• 

Stop Program

• 

Run on power on

• 

Capture DMX 

The editor of the fixture can also capture capture live DMX values, or 

the  DMX  values  can  be  captured  from  the  controller  when  using  the 

‘Control  Channel’.  The  'Control  Channel'  can  be  found  in  the  DMX 

charts table, available at http://www.sgmlight.com, or upon request via                            

[email protected]
To set a single static scene, set the fade time of scene 2 to 0.0 seconds, 

this will keep the fixture running scene 1.
To make a sequence of up to 24 scenes, set the fade time of the scene following the last one to 0.0 seconds. This will keep the fixture 

looping between scene 1 to the scene before the scene with 0.0 seconds fade time.
The copy/paste function offers the ability to create replicas of a previous created scenes.

Editor

Select Editor by pressing OK. The following options will show up: 

•  Scene - Press OK and choose a scene (1 to 24). Confirm with OK.
•  Wait Time - Press OK and set the wait time (0 to 4000 seconds). Confirm with OK.
•  Fade Time - Press OK and set the fade time of the selected scene (0 to 4000 seconds). Confirm with OK.
•  Copy Scene - Press OK to copy the selected scene to the clipboard.
•  Paste Scene - Press OK to paste copied scene from the clipboard to the selected scene.
•  Clear Scene - Press OK to clear the selected scene and set the default settings.

Scroll down in the display to see all controllable features.

To change a value of a feature:

•  Select the feature to change

• 

Press OK and change the value.

• 

Confirm with OK.

Channels operating in 8 bit mode will allow you to set a value from 0 to 255. 

Channels operating in 16 bit mode will allow you to set a value from 0 to 65535.

Using stand-alone operation

Figure 7: Stand-alone operation

Summary of Contents for G-Spot Turbo

Page 1: ...USER MANUAL MOVING HEADS SERIES G SPOT TURBO...

Page 2: ...or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this manual The SGM logo the SGM name and all o...

Page 3: ...l device 10 Configuring the device for DMX control 10 LED refresh rate frequency 11 LED Frequency Settings 12 Fixture properties 13 Effects 13 Control menu 14 Control menu continued 15 Control menu co...

Page 4: ...stall only in accordance with applicable building codes Ensure a minimum clearance of 0 1 m 4 in around the cooling fans Do not paint cover or modify the device and do not filter or mask the light Kee...

Page 5: ...an expected lifetime of 50 000 hours The lightsource of the fixture is expected to run until about 50 000 hours LM 70 TM 21 This manual covers installation use and maintenance of the G Spot Turbo All...

Page 6: ...ce ensure that It is situated away from public thoroughfares and protected from contact with people It is not immersed in water or exposed to high pressure water jets It has adequate ventilation When...

Page 7: ...clamps 5 Install two safety wires that each can bear at least 10 times the weight of the unit The attachment points are designed to fit a carabiner 6 Check that the pan tilt locks are released A and...

Page 8: ...identically Address sharing can be useful for diagnostic purposes and symmetrical control Next DMX Address E Showing the next available DMX address depending on the fixture s DMX footprint ESC OK SGM...

Page 9: ...ight com To set a single static scene set the fade time of scene 2 to 0 0 seconds this will keep the fixture running scene 1 To make a sequence of up to 24 scenes set the fade time of the scene follow...

Page 10: ...gnals sent by a DMX controller on a number of DMX channels which varies depending on the DMX mode that has been set The first channel used to receive data from a DMX control device is known as the DMX...

Page 11: ...rate by setting the Control channel to 0 through DMX whenever possible 0 factory default settings to maintain the best possible dimming performance The refresh rate settings are active as long as the...

Page 12: ...86 80 31 4 2 78 CONTROL CHANNEL DMX Step DMX LED Freq kHz 81 31 8 2 70 82 32 2 2 63 83 32 5 2 56 84 32 9 2 50 85 33 3 2 44 86 33 7 2 38 87 34 1 2 33 88 34 5 2 27 89 34 9 2 22 90 35 3 2 17 91 35 7 2 13...

Page 13: ...includes both breakup patterns geometric gobos and full colored gobos Effect wheels The G Spot Turbo has two effect wheels for generating optical effect The two effect wheels operate as an extension o...

Page 14: ...SMPS Display SMPS temperature Pan Tilt Display pan and tilt temperature Gobo Focus Display gobo and focus temperature Base Head Display base and head temperature Humidity B H Display of humidity in t...

Page 15: ...GOBO 2 SELECT CALIBRATION XXXXX EFFECT WHEEL 1 CALIBRATION XXXXX EFFECT WHEEL 2 CALIBRATION XXXXX FROST CALIBRATION XXXXX PRISM CALIBRATION XXXXX IRIS CALIBRATION XXXXX SERVICE PIN Service use only C...

Page 16: ...lected scene Center 32767 Gobo 1 1 255 Scroll UP and DOWN to set Gobo 1 in currently selected scene according to latest DMX chart Gobo 1 Rot 1 65535 Scroll UP and DOWN to set Gobo 1 rotation in curren...

Page 17: ...Strength Other Humidity Base Other Humidity Head Other Fan 1 Led RPM Velocity Fan 2 Led RPM Velocity Fan Base RPM Velocity Fan Head RPM Velocity Fan Zoom RPM Velocity Errors Other Humidity Absolute Ot...

Page 18: ...hase inverter or replace cables DMX cable is corrupted Replace or repair defective cables and or connections DMX link is not terminated Install a XLR 120ohm DMX termination at the end of the DMX link...

Page 19: ...ed When the head of the fixture is facing upwards cover gobo wheel 2 is located at the side of the head corresponding to the pan lock B 4 Remove the gobo wheel hatch for access to the gobo wheel 5 Tur...

Page 20: ...o maintain the fixture s IP65 rating it is important to fasten the gobo covers to 1 Nm The gobo wheel hatch includes a GORE TEX Membrane which allows the fixture to breathe In order to vacuum test the...

Page 21: ...To change the display saver go to OK SETTINGS DISPLAY OFF This can also be changed via RDM please see RDM on page 17 NOTE To avoid the risk of display deterioration caused by long term use in permane...

Page 22: ...WH P N 80021202 G Spot Turbo Std CU P N 80021203 Single flightcase G Spot with labels P N 82051001 SGM USB uploader cable P N 83062011 Support hotline SGM offers 24 7 technical support hotline Worldwi...

Page 23: ..._ ________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Page 24: ..._ ________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Page 25: ..._ ________________________________________________________________________________________________________ _____________________________________________________________________________________________...

Page 26: ...26 SGM Light A S Sommervej 23 8210 Aarhus V Tel 45 70 20 74 00 info sgmlight com www sgmlight com...

Reviews: