Page  2  of  36

www.sgm-lektra.com

FLOWMETER - 

contents

CONTENTS

 

page   3

page  4

page   5

page   6

page   7

page   9

page   11

page   14

page   36

 

  1-WARRANTY

  2-PRODUCT

  3-PERFORMANCE SPECIFICATIONS

  4-DIMENSIONS

  5-INSTALLATION

  6-ELECTRICAL CONNECTIONS

  7-LOCAL OPERATOR INTERFACE (LOI)-VL601

  8-SETUP

10-FACTORY TEST AND QUALITY CERTIFICATE

Summary of Contents for FLOWMETER

Page 1: ...FLOWMETER ultrasonic flow transmitter technical documentation EN Rev of 19 10 2021...

Page 2: ...TS page 3 page 4 page 5 page 6 page 7 page 9 page 11 page 14 page 36 1 WARRANTY 2 PRODUCT 3 PERFORMANCE SPECIFICATIONS 4 DIMENSIONS 5 INSTALLATION 6 ELECTRICAL CONNECTIONS 7 LOCAL OPERATOR INTERFACE L...

Page 3: ...n the original term of guarantee whereas if the Product is replaced it will have 12 twelve months of guarantee The warranty will be null if the Client modifies repair or uses the Products for other pu...

Page 4: ...2 PRODUCT 1 Anticondensation filter 2 M20 skintop 3 VL601 opt 4 Sensor 2 1 IDENTIFICATION Each meter has an adhesive identification plate on which are the meter main data The following picture describ...

Page 5: ...y 12Vdc 24Vdc Power consumption 1 5W 4 wires Analog output 4 20mA max 750ohm Relays output n 2 3A 230Vac n o Digital communication MUDBUS RTU Max measure range max 0 25 5m In case of non perfectly ref...

Page 6: ...6 of 36 www sgm lektra com 4 DIMENSIONS FLOWMETER dimensions 4 1 MECHANICAL DIMENSIONS 66 127 5 223 55 5 95 127 5 95 2 G 66 232 5 55 5 2 G 239 5 127 5 55 5 PP HOUSING ALUMINIUM HOUSING PP HOUSING EXTE...

Page 7: ...that can be intercepted as level Make sure that there is not foam presence on the product surface to be measured Lobo FLOWMETER 5mt 10 Make sure that the FLOWMETER distance from the weir channel poin...

Page 8: ...com FLOWMETER installation 5 1 2 Blind distance During installation is important to remember that in the sensor vicinity there is a blind zone or BLIND DISTANCE of 0 25m where the sensor can not measu...

Page 9: ...ds 4 Do not use sleeves terminals because they might interfere with the VL601 module insertion 5 Close the cap and tighten the cable glands 6 2 HUMIDITY INFILTRATIONS To avoid the humidity infiltratio...

Page 10: ...module cod 694A004A 3 MODBUS RTU communication S W cod 010F119A for FLOWMETER transmitter With this software is possible connect by selecting the UID address the FLOWMETER transmitters in MODBUS RTU n...

Page 11: ...some parameters the configuration is done by setting a value eg in the SET DISTANCE 4mA parameter is possible to change the the corresponding distance value in mm press to select the digit to be modif...

Page 12: ...1 The VL601 programming module can be mounted and removed from the FLOWMETER without affecting the unit operation Unscrewing the cap the VL601 module can be mounted by clockwise rotation until it clic...

Page 13: ...sition correctness identify any false echo signals that may cause measurement errors 1 5 4 3 2 m D 721mm G 020 57 2KHz The rectangle placed at the echo line base indicates the measurement range within...

Page 14: ...SETUP DISPLAY FLOW APPL SERVICE INFO RELAYS SET MAX FLOW FILTER COEFFICIENT BLIND DISTANCE 137 54 FLOW m h 18369 TOTALIZER m MIN MAX SETUP SET MAX FLOW R ELAYS FILTER COEFFICENT BLIND DISTANCE RL2 DIA...

Page 15: ...UP ARROW and SCROLL to modify the value Press ENTER to confirm LEFT ARROW to exit without changes Default value 0 00000 00 RL1 COUNTER m RL1 COUNTER RL2 THRESHOLD RL2 DIAGNOSTIC 8 2 3 RL2 THRESHOLD P...

Page 16: ...s Default value 00s 00 s DELAY VALUE MIN MAX DELAY SAFETY ENABLE DISABLE 8 2 3 4 ENABLE DISABLE Position the cursor on ENABLE DISABLE press ENTER to confirm Select ENABLE to activate RL2 threshold Sel...

Page 17: ...ng on the display press SCROLL to show a message that indicate what kind of error is present The METER automatically returns to RUN mode RL1 COUNTER RL2 THRESHOLD RL2 DIAGNOSTIC DISABLE ANABLE FLOWMET...

Page 18: ...BLIND ZONE of the sensor Input the desired value in order to avoid measures near the surface of the sensor if necessary The minimum value is 250mm Use UP ARROW and SCROLL to modify the value Press ENT...

Page 19: ...WELCOME TEXT PRIMARY VALUE SECONDARY VALUE 8 4 1 1 PRIMARY SECONDARY VALUES Position the cursor on primary secondary VALUES press ENTER to access Two values are displayed it s possible to choose whic...

Page 20: ...alue of a parameter from 0 to 63 Use UP ARROW and SCROLL to modify the value Press ENTER to confirm LEFT ARROW to exit without changes Default value 16 DISPLAY VALUES SET FLOWRATE LCD CONTRAST WELCOME...

Page 21: ...S500 BS600 BS800 BS1000 SGMVENTURICUSTOM 0000 mm 1 INCH 2 INCH 3 INCH 6 INCH 9 INCH 12 INCH 1 0 FT 18 INCH 1 5 FT 2 FT 3 FT 4 FT 5 FT 6 FT 8 FT 10 FT 12 FT DN100 4in DN150 6in DN200 8in DN250 10in DN3...

Page 22: ...on the cursor on WEIRS press ENTER to access In this sub menu it s possible to select and set the weir kind available in the channel Can be selected Rectangular Suppressed Rectangular Contracted Trape...

Page 23: ...00 mm RECT CONTRACTED C L C 2 x i max L min 0 15m minimum p 2 x i max p i min 250mm minimum 3 x i max 3 3 4 5 8 6 1 1 3 TRAPEZOIDAL Position the cursor on TRAPEZOIDAL or Cipoletti ENTER to confirm To...

Page 24: ...0 V NOTCH min 2 x i E 20 e 100 p min 0 4mt minimum p 2 x i max min 250mm minimum 3 x i max p i 3 3 4 5 TRIANGULAR WEIR 8 6 1 2 FLUMES Position the cursor on flumes press ENTER to confirm In this sub...

Page 25: ...ARROW to exit without changes SGM VENTURI STD SGM VENTURI CUSTOM KHAFAGI VENTURI PARSHALL INCH PARSHALL FEET PALMER BOWLUS PALMER BOWLUS 2 BS 150 BS 200 BS 300 BS 400 BS 500 BS 600 BS 800 BS 1000 8 6...

Page 26: ...LMER BOWLUS 2 QV302 120mm QV303 300mm QV304 400mm QV305 500mm QV306 600mm QV308 800mm QV310 1000mm QV313 1300mm 8 6 1 2 4 PARSHALL INCH Position the cursor on PARSHALL INCH press ENTER to confirm PARS...

Page 27: ...5 ft 6 ft 8 ft 10 ft 12 ft 8 6 1 2 6 PALMER BOWLUS PALMER BOWLUS 2 Position the cursor on palmer bowlus or palmer bowlus 2 press ENTER to confirm PALMER BOWLUS are prefabricated Palmer Bowlus channels...

Page 28: ...ly with the MUDBUS communication software code 010F119A WEIRS FLUMES TABLE CUSTOM 8 6 1 4 CUSTOM Position the cursor on Custom press ENTER to confirm It s only possible to see those parameters The par...

Page 29: ...US FROZEN GAIN MAX GAIN TH PEAK VALUE START TOTALIZER ALARM CONFIGURATION 0120 mm SET ACTUAL HEAD WARNING Proper programming of this parameter is essential for correct flow measurement Do not proceed...

Page 30: ...RIMARY DEVICE SELF CALIBRATION MEASURE STATUS FROZEN GAIN MAX GAIN TH PEAK VALUE START TOTALIZER ALARM CONFIGURATION 000 FROZEN GAIN 8 6 5 MAX GAIN TH Position the cursor on MAX GAIN TH press ENTER to...

Page 31: ...ESET VALUES press ENTER to start the the flow totalizer After starting the totalizer is not possible to stop the totalization PRIMARY DEVICE SELF CALIBRATION MEASURE STATUS FROZEN GAIN MAX GAIN TH PEA...

Page 32: ...he operation mode Press ENTER to confirm LEFT ARROW to exit without changes Default value HOLD LAST VALUE OUTPUT SAVE MODE SET UID LANGUAGE OUTPUT SIMULATION F WINDOW RESTORE SETTING 21 5 mA 3 85 mA H...

Page 33: ...on the cursor on F_WINDOWS press ENTER to access It is the increase value in cm step to step of the window width during the echo signal research phase The F_WINDOWS is the area where the echo receptio...

Page 34: ...revision and the configuration index SETUP DISPLAY FLOW APPL SERVICE INFO FIRMWARE REV I C SGM LEKTRA FLOWMETER FLOWMETER configuration 8 8 6 RESTORE SETTING Position the cursor on SET UID press ENTER...

Page 35: ...Page 35 of 36 www sgm lektra eu...

Page 36: ...in conformity to the procedure Quality Control Manager Production and check date SGM LEKTRA S r l Via Papa Giovanni XXIII 49 20053 Rodano MI ITALY tel 39 02 95328257 fax 39 02 95328321 e mail info sg...