8
1
DESCRIPTION
SANICOMPACT
®
Eco
is a WC specially designed with
an integral pump/macerator.
SANICOMPACT
®
Eco
is for
domestic use.
Installed and used correctly,
SANICOMPACT
®
Eco
will give
consistent and reliable service.
Please note the following warning signs:
«
» Possible danger to personnel,
«
» Warning of possible electrical hazard.
«
WARNING
» This is a general warning that failure to
follow instructions could result in poor functioning
of the unit.
OPERATING PRINCIPLE
SANICOMPACT
®
Eco
is controlled by an electronic
programmer.
It has a macerating and pumping function. To start press
one of the two grey sides (light grey: small flush, dark grey:
large flush) of the button integrated to the bowl.
2
LIST OF ACCESSORIES INCLUDED
3
DIMENSIONS
4
TECHNICAL DATA
Applications
discharge of a WC
Type
CR15 DF
Maximum Vertical Pumping
3 m
Voltage
220-240 V
Frequency
50 Hz
Normal Power Rating
550 W
Maximum current consumption
2,5 A
Electric Class
I
Degree of protection
IP44
Maximum water temperature
35°C
Net Weight
C3
28,6 Kg
C5
29,0 Kg
C6
26,5 Kg
C43
23,2 Kg
C48
25,4 Kg
WARNING:
Only installations conforming to the above
specifications are acceptable.
5
PERFORMANCE CURVE
6
INSTALLATION
6a
ATTACHING THE TOILET TO THE FLOOR
Place the
SANICOMPACT
®
Eco
in the desired location.
Trace round the position of the bowl and mark the postition
of the fixing screws. Remove the bowl and then mark the
position of the fixing brackets 15mm inside the drawn line
(see dia
6a
).
Remove the toilet bowl.
Drill through the flooring.
If necessary, and if you have time, lay a silicone joint
around the location of the toilet bowl.
Install the fixing screws and brackets. Put the
SANICOMPACT
®
Eco
in place. Use the screws to fix the
SANICOMPACT
®
Eco
to the floor.
6b
CONNECTION OF THE DISCHARGE
1 - Fully insert the elbow
H
a
in the end of the rubber
waste tube, after turning it to face in the desired
direction.
2 - Fix the base of the elbow
H
a
and tighten it on the
rubber waste tube with a clamp
D
.
3 - Connect the sleeve
H
b
to the end of the elbow with
the clamp
D
. Cut off the end of the sleeve to adapt it to
the waste pipe. Connect the 32mm wastepipe into the
sleeve and secure with jubilee clip
C
.
4 -
Warning:
Ensure that you do not twist the discharge
pipework inside the unit.
5 -
Warning:
The horizontal portion of the discharge pipe
should be installed in a gravity flow, (1/4 inch to 1 foot).
Avoid any low parts in the discharge pipe.
6 -
Warning:
Protect pipes against freezing with appro-
priate insulation. If the toilet is installed in an unheated
location during freezing periods protect it as follows:
• Shut off the water supply,
• Activate one cycle without water,
• Pour antifreeze in the bowl (2 litres),
• Flush the toilet.
7 -
Warning:
Any bends in the discharge pipe run should
be smooth radius bends. If using plastic pipe two 45
degree offsets can be used to form a smooth bend.
8 -
Note:
We would recommend that a drain-off point is
installed to allow the discharge pipework to be drained
down before any service work.
9 -
Note:
To avoid siphoning, install a an anti-siphon valve
at the high point of the installation.
6c
CONNECTION TO THE WATER SUPPLY
Connect the water supply hose to a shut off valve
Caution: The quality of the rinsing of the bowl depends on
the water pressure.
WARNING:
for a correct rinsing, the water pressure should
be at least 25 PSI
(1,7 bars)
.
Note:
In an area where water is not pure (dirty, sandy), we
advise you to add a filter between the shut off valve and the
toilet to prevent clogging of the solenoid valve.
6d
CONNECTION TO THE ELECTRICAL SUPPLY
The electrical installation should be carried by a
qualified person.
All wiring must conform to BS7671, 1992 requirements for
electrical installation. The unit requires a 220/240 V single
phase AC 50 Hz supply (UK specification). Do not connect
the unit to a conventional plug and socket. The unit should
be connected to a fully earthed electrical supply (class 1).
It must be wired into an unswitched fused fixed wiring
connector protected by a 5 amp fuse and a residual cur-
rent detector (30 mA). This connection must be used
exclusively for supplying the unit.
The wires in the mains lead are coloured in accordance
with the following code:
Brown
–
Live
Blue
–
Neutral
Green/Yellow –
Earth
WARNING:
Ensure the electricity is turned OFF at the main
switch board before wiring to connector. All work on cable,
pressure chamber and motor should only be carried out
by a qualified Saniflo servicing agent, as special tools are
required.
UK
Fully illustrated step by step instructions are
downloadable on www.saniflo.co.uk
9008 SANICOMPACT ECO N°107.indd 8
14/06/10 12:30:20
Summary of Contents for SANICOMPACT Eco 43
Page 2: ...9008 SANICOMPACT ECO N 107 indd 2 14 06 10 12 30 15 ...
Page 32: ...32 RO DF 9008 SANICOMPACT ECO N 107 indd 32 14 06 10 12 30 25 ...
Page 33: ...33 9008 SANICOMPACT ECO N 107 indd 33 14 06 10 12 30 26 ...
Page 34: ...34 DF 9008 SANICOMPACT ECO N 107 indd 34 14 06 10 12 30 27 ...
Page 35: ...35 7a 7b 9008 SANICOMPACT ECO N 107 indd 35 14 06 10 12 30 28 ...
Page 37: ...37 NOTES 9008 SANICOMPACT ECO N 107 indd 37 14 06 10 12 30 29 ...
Page 38: ...38 NOTES 9008 SANICOMPACT ECO N 107 indd 38 14 06 10 12 30 29 ...
Page 39: ...39 NOTES 9008 SANICOMPACT ECO N 107 indd 39 14 06 10 12 30 29 ...