- 26 -
SI 400 DIGITAL INDICATOR
318
Ethernet
Stream mode DATA
Transference Format selection
(Option Port)
00
00 : Format 1 (19byte)
01 : Format 2 (22byte)
02 : Format 3 (17byte)
03 : Format 4 (22byte)
05 : Format 5 (15byte)
319
Ethernet
Stream mode Data
transference
(Option Port)
00
00 : Countinuously
01 : Single time on every steady state
02 :
At the first steady point
03 :
When Finish Relay output
1time
output
04 :
When input print key
352
Print Format Setting
00
00: Continuous Print, 01: Single Print
354
Print Output Delay Time Setting
00
00~10 (Unit:1sec.)
355
Paper Withdraw after printing out
(Continuous print or single print)
00
00~10 (Unit:1line add)
356
Paper Withdraw after Grand-total
printing out
00
00~10 (Unit:1line add)
357
After Sub Print, Sub data Deleted
00
00 : Not Delete
01 : Delete
358
Deleting Grand-total data after printing
out
00
00:Delete 01:No delete
401
Analog Output Applying Weight Range
Setting
00
00: Absolute number(-&+)
01: Positive number(only +)
402
Analog Output Direction Setting
00
00:Forward 01:Reverse
403
Analog Output Standard Setting
00
00 : CAPACITY
01 : CAPACITY(Gross weight under Tare)
404
BIN IN (Product number change)
00
00 : Disuse
01 : Units digit, tenth digit separation
02 : Units digit, tenth digit No
separation
405
IP Setting 1
-
0~255
406
IP Setting 2
-
0~255
407
IP Setting 3
-
0~255
408
IP Setting 4
-
0~255
409
Subnet Mask Setting 1
-
0~255
410
Subnet Mask Setting 2
-
0~255
411
Subnet Mask Setting 3
-
0~255
412
Subnet Mask Setting 4
-
0~255
413
Gate Way Setting 1
-
0~255