10
l
the digital display is supported by the
lower segment display:
l
1st bar
-
from 10 ppm
2nd bar
-
from 100 ppm
3rd bar
-
from 200 ppm
4th bar
-
from 500 ppm
5th bar
-
from 0.10 vol.%
6th bar
-
from 0.20 vol.%
7th bar
-
from 0.50 vol.%
8th bar
-
from 1.00 vol.%
2.3
2.3
2.3
2.3
2.3
Concentration-dependent signal
Concentration-dependent signal
Concentration-dependent signal
Concentration-dependent signal
Concentration-dependent signal
l
the frequency of the acoustic signal
(item 3) increases as a function of the
concentration measured
l
this signal can be switched on and off
with the service key (item 6) on the back
of the detector
☞
Insert the adjusting pin (supplied)
Insert the adjusting pin (supplied)
Insert the adjusting pin (supplied)
Insert the adjusting pin (supplied)
Insert the adjusting pin (supplied)
into the hole and press the service
into the hole and press the service
into the hole and press the service
into the hole and press the service
into the hole and press the service
key behind it (item 6).
key behind it (item 6).
key behind it (item 6).
key behind it (item 6).
key behind it (item 6).
l
the acoustic control signal (item 3)
sounds and the concentration-
dependent signal is switched off
l
pressing the service key again switches
the signal back on
Summary of Contents for EX-TEC SNOOPER H
Page 1: ...Instructions Wir sichern Lebensqualität Operating 102729 ...
Page 3: ...1 Design of the EX TEC SNOOPER H ...
Page 4: ...2 Notes ...
Page 29: ...27 EC Type Examination Certificate ...
Page 30: ...28 EC Type Examination Certificate ...
Page 31: ...29 Declaration of Conformity EX TEC SNOOPER H ...
Page 34: ...32 Notes ...