76
│ 8 Faults and problems
8
Faults and problems
8.1
Error messages
If a fault occurs during operation, an error message will appear on
the display. Error messages are displayed in the order in which
they occur. Up to 5 errors can be displayed.
The update rate for error messages is max. 1 second. Error mes-
sages continue to be displayed until the error is corrected.
Error messages with error code 7 – 59
Error
code
Errors
Corrective action
7
Sensor not adjusted: EC Adjust device!
8
Sensor not adjusted: PX Adjust device!
9
Sensor not adjusted: IR Adjust device!
10
Adjustment error.
Check test gas!
Otherwise sensor faulty.*
11
Zero point not OK.
Adjust device!
52
Memory error: XFlash
Contact SEWERIN Service!**
59
Voltage error.
Contact SEWERIN Service!
* Check that the test gas selected in the device corresponds to the test
gas actually used. If the test gas is correct, a faulty sensor may have
caused the error message. In that case contact SEWERIN Service.
** First try to fix the error by
restoring
the device (section 4.3.3).
Error messages with error code 60 - 64
Error
code
Errors
Corrective action
60
Sensor error: PX/CC
Contact SEWERIN Service!
61
Sensor error: PX/TC
Contact SEWERIN Service!
62
Sensor error: IR
Contact SEWERIN Service!
63
Sensor error: PX
Contact SEWERIN Service!
64
Sensor error: PX/SC.
Contact SEWERIN Service!