6 Maintenance
│
61
6.4.7.7 Performing a bump test (ECO device inspection)
The
Warning ECO
application is selected for the device in-
spection.
1. Select
Bump test
.
2. Select a test gas from the list.
3. If the following message appears:
Add test gas!
●
Add the test gas.
To do so, connect the test gas hose of the
SPE AutoFlow
to the gas input of the device.
4. Wait while the following message is visible:
Add more test
gas! Process ongoing …
5. If the following message appears:
Stop test gas!
●
Disconnect the test gas hose from the gas inlet.
6. When the bump test is complete, an overview of the tested
gases will appear.
The device returns to the test gas selection.
7. If necessary:
●
Repeat the bump test for other gases.
8. Press the Menu key. The device switches back one menu
level.
6.4.7.8 Save the device inspection
Fully performed device inspections as well as subtests can be
saved in the device.
The entire device inspection or subtests were performed for
a selected application.
1. Select
Save
. The device inspection is saved.
2. If users have been created for the device
3
:
●
Select a user from the list.
3. If necessary:
●
Enter the PIN code of the user.
The device inspection is saved.