7
Startup
Startup procedure
Manual – PROFINET IO Interfaces, Field Distributors
82
CW/stop
CCW/stop
Meaning
Not activated
Not activated •
The device is inhibited or the drive is brought to a
stop.
L
R
24V
11.
WARNING!
Uncontrolled enable of an unexpected drive due to incorrect ad-
dress setting. Severe or fatal injuries.
Make sure that the S1/1 and S1/2 DIP switches on the MFE.. PROFINET IO inter-
face are set depending on the field distributor according to the following figures:
MFZ21, MFZ23, MFZ26, MFZ27, MFZ28
1
4
3
2
O
N
S1
res. (OFF)
res. (OFF)
DEF-IP (OFF)
MFZ29 (OFF)
MFZ29
1
4
3
2
O
N
S1
res. (OFF)
res. (OFF)
DEF-IP (OFF)
MFZ29 (ON)
12. Place all MOVIMOT
®
inverters, the MFE.. fieldbus interface and the cover plate
(only for MFZ29) on the field distributor and tighten with screws.
Observe the notes on installation of the MOVIMOT
®
inverters at the MFZ29 field
distributor (→
13.
WARNING!
Uncontrolled enable of an unexpected drive by swapping the
MOVIMOT
®
inverters (only for MFZ29). Severe or fatal injuries.
Install the MOVIMOT
®
inverters of the MFZ29 field distributor based on the set
RS485 address according to the following figure:
1415
13
12
11
1
2
3
4
5
1
2
3
4
5 6
7
8 9
12
11
10
1
2
3
4
5 6
7
8 9
12
11
10
1
2
3
4
5 6
7
8 9
12
11
10
0 1 2
0 1 2
1
ON
3
3
2
1
ON
2
3
1
ON
3
3
2
1
ON
2
3
S1
1
ON
3
3
2
1
ON
2
3
S1
S1
RS485 = 1
MOVIMOT 1
®
MOVIMOT 2
®
MOVIMOT 3
®
RS485 = 2
RS485 = 3
18403922443
14.
WARNING!
Electric shock due to missing cover. Severe or fatal injuries.
If you install only 1 or 2 MOVIMOT
®
inverters at the field distributor, you have to
cover all free slots with the delivered covers. Make sure that there are no open
slots.
22870857/EN – 12/2016