4
Electrical installation
Assignment of the optional plug connectors at MGF..-DFC and MGF..-DSI
Revision – MOVIGEAR
®
performance
22
4.4.2
X2327: PA connection for AC 400 V and 24 V backup voltage (OUT)
The following table shows information about this connection:
Function
PA connection for AC 400 V and 24 V backup voltage (OUT)
Connection type
M23, female, female thread with union nut, SEW insert, 723 series, SpeedTec equip-
ment, company: TE Connectivity – Intercontec products, male, coding ring: black/
green, protected against contact
Connection diagram
PE
U
A
B
W
V
Assignment
Contact
Signal
Description
U
L1
Line connection, phase L1 (OUT)
V
L2
Line connection, phase L2 (OUT)
W
L3
Line connection, phase L3 (OUT)
PE
PE
PE connection
A
+24V
DC 24 V output for backup mode (OUT)
B
0V24
0V24 reference potential for backup mode (OUT)
26920468/EN – 06/2020