4
Electrical installation
Assignment of the optional plug connectors at MGF..-DFC and MGF..-DSI
Revision – MOVIGEAR
®
performance
18
4.4
Assignment of the optional plug connectors at MGF..-DFC and MGF..-DSI
4.4.1
X1216: PA connection for AC 400 V and 24 V backup voltage (IN)
The following table shows information about this connection:
Function
PA connection for AC 400 V and 24 V backup voltage (IN)
Connection type
M23, male, male thread, SEW insert, 723 series, SpeedTec equipment, company:
TE Connectivity – Intercontec products, male, coding ring: black/green, protected
against contact
Connection diagram
PE
V
B
A
W
U
Assignment
Contact
Signal
Description
U
L1
Line connection, phase L1 (IN)
V
L2
Line connection, phase L2 (IN)
W
L3
Line connection, phase L3 (IN)
PE
PE
PE connection
A
+24V
DC 24 V input for backup mode (IN)
B
0V24
0V24 reference potential for backup mode (IN)
26920468/EN – 06/2020