3
Safety-related conditions
Operation requirements
Manual – Functional Safety
16
INFORMATION
The insert labels of the MOVIFIT
®
EBOXes are assigned to the respective EBOX. If
you take out the labels to mark them, make sure that they are re-inserted in the right
EBOX.
To avoid danger in the application, the user has to check whether the fault response
time of each safety function (when a failure occurs) is shorter than the maximally per-
mitted fault response time of the application. The maximum permitted fault response
time may not be exceeded!
3.5
Operation requirements
•
Operation is only permitted within the limits specified in the data sheets. This ap-
plies to the external safety control as well as to MOVIFIT
®
and MOVIMOT
®
.
•
You must check the safety functions on a regular basis to ensure proper function-
ing. The test intervals should be specified in accordance with the risk assessment.
29157056/EN – 09/2019