8
Startup with PROFINET
Setting up the PROFINET IO controller
Manual – MOVI-C
®
CONTROLLER progressive UHX65A-M
33
6. Open the context menu of the PROFINET IO controller with a right click and select
the option "Scan for devices...".
35944445579
7. A new dialog window will open that lists all connected PROFINET IO devices of
the network. An unambiguous and PROFINET-compliant station name as well as
an IP address must be assigned for the initial startup of a PROFINET IO device.
35943692171
INFORMATION
Should the scan not output any results despite correct network settings and cabling,
there may possibly still be a missing PROFINET IO controller license on the
MOVI-C
®
CONTROLLER UHX65A-M. Open the license manager in MOVISUITE
®
and
check
the
licenses.
After
activating
the
licenses,
restart
the
MOVI-C
®
CONTROLLER UHX65A-M with a 24 V reset.
26881144/EN – 02/2022