Software - configuration & parameterizing
76
Software - configuration & parameterizing
20
258
_10
0300
06/EN - 0
3/2
022
Operating manual [27779289/EN] - MAXO-RG single-axis controls
20.4.5
Parameter: Collision protection sensor
Parameter
Selection
Description
Input
No input
Selecting the digital input for activating the colli-
sion protection function.
If "no input" is selected, the collision protection
function is deactivated.
E1 ... E12
Active state
input
LOW
Selected digital input active state for enabling
the collision protection function.
HIGH
Active direc-
tion
CW/CCW
Motor rotation valid direction for triggering the
collision protection function.
CW
CCW
Deceleration
ramp
Deceleration ramp
Speed 0 ... 9
Deceleration ramp for stopping when the colli-
sion protection function is triggered.
Emergency stop
Deceleration ramp
Restart delay 0 ... 65000ms
Restart delay