Diagrams and Conventions used in the Text (cont.)

MP10 Display:

00.1

MP CPM4

>05.0

103

10.0

Discharge time
setting in 
seconds

Indicates if 
pump is
Refilling or
Discharging

Cycles per
minute setting

The mode the
controller is in

Refill time
setting in
seconds

Time
remaining
in the cycle

ID for time
settings

Abbreviations:

CPM

MP

ID

HELD

MN

BAT

LVL

>

Cycles Per Minute

MicroPurge Mode

ID Time Set Mode
Held In A Cycle

Manual Time Set Mode
Battery

Level Pause

Indicates Refill Or Discharge Cycle

Summary of Contents for QED MicroPurge basics MP10

Page 1: ...1 800 624 2026 FAX 734 995 1170 info qedenv com www qedenv com 1133 Seventh Street Oakland CA 94607 2601 1 800 537 1767 FAX 510 444 6789 QED ENVIRONMENTAL SYSTEMS Ground Water Sampling Remediation Lea...

Page 2: ...MP10 Controller Optional MP30 Drawdown Meter Well Cap Tubing Air Supply In Pump Air Supply Pump Discharge Well Wizard Bladder Pump R MP10 Basic Setup...

Page 3: ...the MP10 On Opening Display MicroPurge Mode Using CPM Sampling Use with the MP30 Level Sensing Water Level Meter ID Mode User Time Set MN Mode MP10 Battery Troubleshooting MP10 Specifications QED Serv...

Page 4: ...ng instructions before operating the MP10 controller Warning Do not disassemble the pneumatic pump while it is connec ted to a compressed gas source Dangerous pressures could cause injury Diagrams and...

Page 5: ...MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 103 10 0 MP CPM4 05 0 D D E E C...

Page 6: ...f pump is Refilling or Discharging Cycles per minute setting The mode the controller is in Refill time setting in seconds Time remaining in the cycle ID for time settings Abbreviations CPM MP ID HELD...

Page 7: ...de water level feedback The MP30 uses a stan dard conductivity probe to detect the ground water surface and a marked tape allowing the user to measure the depth When the meter is set in MicroPurge mod...

Page 8: ...approximate depth of the sample pump Follow instructions on the battery panel Opening the MP10 case turns power ON Select desired Cycles Per Minute CPM with default value is 4 CPM lower CPM for deeper...

Page 9: ...red with its lid closed Opening Display The opening display is shown for 5 seconds and displays the controller name the version number and the battery voltage as shown in Figure 1 Figure 1 shows that...

Page 10: ...ode Figure 2 MP10 MicroPurge Mode Using CPM The MP10 introduces a revolutionary simpler way to con trol bladder pump flow rate and achieve the low flow method used by experts Up down arrow keys are us...

Page 11: ...ayed in the lower left corner of the display indicates Micro Purge mode The default CPM setting of 4 cycles per minute is a good starting point for wells with depths from 25 100ft MicroPurge mode star...

Page 12: ...he pump fills and waits Pressing the PAUSE key a second time causes the controller to immediately enter the Sample state Drive air is directed to the pump causing the pump to discharge its volume of l...

Page 13: ...his allows easy adjustment of the 2 throttle giving pressures that will produce gentle non turbulent flow normally 10 20 Feet H O deeper than pump depth For traditional 2 high volume purging pressure...

Page 14: ...ler MP Micro Purge ID ID Time Set MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00...

Page 15: ...ig nals the MP10 to resume pump operation The MP10 resumes by start ing in the refill leg of the pump cycle The normal operating mode for using the MP30 with the MP10 is 1 Use the MP30 in standard WLM...

Page 16: ...ditional information on the MP30 is given in the MP30 O M manual OPERATION ID Mode Figure 6 shows an example of the MP10 in ID time set mode Once you ve used the MP10 in MP mode and found proper setti...

Page 17: ...econds will time out before a new refill time becomes valid User Set Mode A final controller mode User Set mode MN on the display is useful for manually setting refill and discharge times on the contr...

Page 18: ...battery life A fresh set of AA batteries will pro vide more than 100 hours of controller operation at normal operating temperatures As ambient temperatures drop below 15 20F 9C to 6C the ability of th...

Page 19: ...en in MP mode Temperature below 10F Warm controller Air not cycling through controller Throttle turned too low Turn throttle clock wise to produce pressure Air source not delivering air Verify air sou...

Page 20: ...s intr oduced from improper battery installation or switch connections LCD display 32 character 2 lines 16 charact ers each Non glare double hardened optical acrylic Sealed NiCd battery pack and 3 use...

Page 21: ...e defective product with a comparable new unit at no charge to the Buyer or to refund the full purchase price In no event shall such allegedly defective products be returned to QED without its consent...

Page 22: ...e If the return of a component is determined to be necessary QED will authorize the return of the component at owner s expense If the product proves not be defective within the terms of this warranty...

Page 23: ...13 5 13 12 5 12 11 5 11 10 5 9 5 9 8 5 8 7 5 7 6 5 6 5 5 5 10 30 31 32 33 34 35 36 37 38 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38...

Reviews: