SETRONIC Verona
35
Menu Ad jus tment
-
it is possible to read the TX and RX values in real time
without necessarily having to go through the Auto Adjustment procedure
(chapter 6.1). You can also carry out manual adjustment of the TX level
< Sensibility >
Go into the set-up menu as explained on page 30.
Press the key
once to go to the Adjustment menu.
< Adjustment >
Press OK to enter the menu.
RX: 100.8%
TX: 10.5%
With the key
you can increase or decrease the
TX value if necessary.
Data not changed
OK to exit
If the TX threshold setting has stayed the same as
that already in memory, the following message
appears.
Saving data...
Once the infrared level regulation has been
completed, press OK to save the data and return to
the previous menu
If it is necessary to stay in this screen for some time you have to press the keys
or
within 1 minute to stop the control unit automatically exiting the
menu.
Loading Data
From Detector
Wait a couple of seconds for the control unit to read
the detector data.
P RE S S
OK
W A I T F OR 2 S E C ON D S ,
T H E N P RE S S
OK
P RE S S
OK
E
N
G
L
IS
H