General

Supply voltage (Class III)

for 0-10 V output:

15-35 VDC or 15-29 VAC

for 4-20 mA output:

10 -35 VDC

Current consumption

DC supply:

typ. 10 mA

AC supply:

typ. 20 mA

Load resistor (for 4-20 mA output)

R

L

 < (U

V

-10 V/0.02 A)[Ω]

Connection

Screw terminals, max. 2.5 mm

2

Housing material

Cast away - AlSi

9

Cu

3

Protection class

IP65/ NEMA 4

Outputs

0-100% RH

0-10 V: 

-1 mA < I

L

 < 1 mA

4-20 mA (2-wire):

R

L

 < 500 Ω 

T dependence of analog outputs

Max. 0.2 mV/°C

Resp. 1 μA/°C

General (cont.)

Cable fitting

PG9

cable Ø 4.5-100 mm (0.18-0.39”)

Sensor protection

Membrane filter

Electromagnetic compatibility

EN61326-1, EN61326-2-3, Industrial environment

Temperature ranges

Operating: -40 to  60°C (-40 to 140°F)

Storage:  -40 to  60°C (-40 to 140°F)

10.0 Technical data

11.0 Spare parts and accessories

Specifications subject to change without notice.

Category

EE Accessory P/N

Setra Accessory P/N

Description

Filters

HA010101

SRHMF

Membrane filter

Filters

HA010103

SRHSS

Stainless steel sintered filter

Filters

HA010104

SRHPG

Plastic grid filter

Filters

HA010105

SRHPF

PTFE - filter Ø12mm

Filters

HA010106

SRHMG

Metal grid filter

Filters

HA010115

SRHHP

H2O2 - filter

Flanges

HA010201

SRHSMF

Stainless steel mounting flange 12mm

Flanges

HA010209

SRHDMK

Duct mounting kit (for SRH400)

Flanges

HA010211

SRHWMC

Wall mounting clip for probe Ø12mm

Flanges

HA010214

SRHPMFB

Plastic mounting flange 12mm; black

Flanges

HA010202

SRHPMFG

Plastic mounting flange 12mm; grey (RAL7035)

Part configuration adapter

EE-PCA

SETRAPCA1

Configuration adapter transmitter to RS232 and USB

Part configuration adapter

HA011057

SETRAPCA4

Configuration cable for humidity & temp probe SRP4xxx

Cable for SRH400

HA010801

SRC400W

Remote probe extension cable - 2 meter

Cable for SRH400

HA010802

SRC400F

Remote probe extension cable - 5 meter

Cable for SRH400

HA010803

SRC400X

Remote probe extension cable - 10 meter

RH & temp sensor probe SRH400

EE07-MFT6HC01

SRP400HTMGM

SRH400 humidity/ temperature sensor with coating

Temp sensor probe SRH400

EE07-MT

SRP400TPNNM

SRH400 temperature sensor

Calibration

ISO-AH3ASD

SRH400SCAL

SRH400 calibration (ISO)

Calibration

OEKD-AH3A1SD

SRH400NCAL

SRH400 calibration (NIST)

Summary of Contents for SRH400

Page 1: ...Setra Systems Inc 159 Swanson Road Boxborough MA 01719 800 257 3872 www setra com Operating Instructions Model SRH400...

Page 2: ...t is for information purposes only and is subject to change without notice Setra Systems assumes no responsibility for any errors or for consequential damages that may result from the use or misrepres...

Page 3: ...8 0 RH and T adjustment of probes 8 1 Definitions 8 2 S07 adjustment with SRH400 basic device 8 3 1 point RH and T adjustment 8 4 Return to factory calibration 8 5 Loop adjustment and calibration in...

Page 4: ...led in a manner that does not have a negative effect on its safe use The user is responsible for observing all applicable safety guidelines local and international with respect to safe installation an...

Page 5: ...as on the optional display One or two point adjustment for RH and T of the transmitter canbeeasilyperformedwithpushbuttonsontheelectronics boardoftheSRH400basicunit Alternatively theprobescanbe adjus...

Page 6: ...H400 version with remote probe please see below 4 4 probes connected to SRH400 with extension cables SRH400 with remote sensing probe The probes can be also connected to the SRH400 housing with extens...

Page 7: ...e electrically isolated from the GND Locate the SRH400 the probe cable and the output cables as far as possible from sources of electromagnetic disturbances For the analogue outputs use either shielde...

Page 8: ...on indicates adjustment mode 1 flash confirms reset to factory calibration 4 S1 Functions 1 point RH or T adjustment RH 50 RH T within the upper half of the T scale 2 point RH or T adjustment high ca...

Page 9: ...hall remain constant Allow min 30 min stabilization time for RH calibration or adjustment If needed clean the sensors and replace the filter cap by a new one 8 2 1 2 point RH and T adjustment 1 Set th...

Page 10: ...S2 for 5 seconds The return to factory calibration is indicated by one flash of the LED Calib 8 5 Loop adjustment and calibration in the field Loop calibration or adjustment in the field as required b...

Page 11: ...15 35 V DC 15 29 V AC power supply 20 35 V DC RL 500 11 35 V DC RL 50 SRH400 Analog volts For the SRH400 with current output an ammeter shall be connected as in Fig 6 power supply for 0 1 V 10 35 V D...

Page 12: ...tput Iout mA 16 Ref Tmax 4 mA For voltage output Uout V Abb Ref Tmax Where Abb voltage scaling 1 V 5 V 10 V Ref reference value of temperature 45 C 113 F resp 5 C 41 F Tmax max temperature scaling e g...

Page 13: ...ers HA010103 SRHSS Stainless steel sintered filter Filters HA010104 SRHPG Plastic grid filter Filters HA010105 SRHPF PTFE filter 12mm Filters HA010106 SRHMG Metal grid filter Filters HA010115 SRHHP H2...

Page 14: ...To assure prompt handling please make sure the RMA number is on the outside of the box and a copy of the service request from is included in the shipment If applicable include a copy of the PO for re...

Page 15: ...s notified in advance of and the product is returned to SETRA transportation prepaid Unless otherwise specified in a manual or warranty card or agreed to in writing and signed by a SETRA officer SETRA...

Page 16: ...Setra Systems Inc 159 Swanson Road Boxborough MA 01719 800 257 3872 www setra com SS SRH400 Rev B 09 2018...

Reviews: