4.0 Returning products for repair

Setra Systems cannot accept a Model AXD for repair unless the Form AXDERN is completes. Contact Setra Systems for an 

ERN number or the form AXDERN. Form AXDERN is included in this guide on page 15.

Please contact a Setra application engineer (800-257-3872, 978-263-1400) before returning unit for repair to review information 

relative to your application. Many times only minor field adjustments may be necessary. When returning a product to Setra, 

the material should be carefully packaged and shipped prepaid to:

Setra Systems, Inc.

159 Swanson Road

Boxborough, MA 01719-1304

Attn: Repair Department

To ensure prompt handling, please supply the following information and include it inside the package or returned material:

•  Name and phone number of person to contact.

•  Shipping and billing instructions.

•  Full description of the malfunctions.

•  Identify any hazardous material used with the product.

NOTES:

Please remove any pressure fittings and plumbing that you have installed and enclose any required mating electrical connectors 

and wiring diagrams.

Allow approximately 3 weeks after receipt at Setra for the repair and return of the unit. Non-warranty repairs will not be made 

without customer approval and a purchase order to cover repair chargers.

Calibration Services

 

Setra maintains a complete calibrations facility that is traceable to the National Institute of Standards and Technology 

(NIST). If you would like to recalibrate or recertify your Setra pressure transducers or transmitters, please call our Repair 

Department at 800-257-3872 (978-263-1400) for scheduling.

5.0 Limited warranty & limitation of repair

SETRA warrants its products to be free from defects in materials and workmanship, subject to the following terms and 

conditions:  Without charge, SETRA will repair or replace products found to be defective in materials or workmanship within 

the warranty period; provided that:

a) the product has not been subjected to abuse, neglect, accident, incorrect wiring not our own, improper installation 

or servicing , or use in violation of instructions furnished by SETRA;

b) the product has not been repaired or altered by anyone except SETRA or its authorized service agencies;

c) the serial number or date code has not been removed, defaced, or otherwise changed; and

d) examination discloses, in the judgment of SETRA, the defect in materials or workmanship developed under normal 

installation, use and service; 

e) SETRA is notified in advance of and the product is returned to SETRA transportation prepaid.

Unless otherwise specified in a manual or warranty card, or agreed to in a writing signed by a SETRA officer, SETRA pressure 

and acceleration products shall be warranted for one year from date of sale.

The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not limited to, any implied warranty 

of merchantability for a particular purpose.

SETRA’s liability for breach of warranty is limited to repair or replacement, or if the goods cannot be repaired or replaced, to 

a refund of the purchase price.

SETRA’s liability for all other breaches is limited to a refund of the purchase price.  In no instance shall SETRA be liable for 

incidental or consequential damages arising from a breach of warranty, or from the use or installation of its products.

No representative or person is authorized to give any warranty other than as set out above or to assume for SETRA any other 

liability in connection with the sale of its products.

For all CE technical questions, contact Setra Systems, USA. EU customers may contact out EU representative Hengstler GmbH, 

Uhlandstr. 49, 78554 Aldingen, Germany (Tel: +49-7424-890, Fax: +49-7424-89500).

Setra Systems, Inc.

159 Swanson Road, Boxborough, MA 01719
800.257.3872  •  www.setra.com

SSAXD REV

. A 4/2019

Summary of Contents for AXD

Page 1: ...ly standard pipe fittings and procedures should be used However for pressure ranges in excess of 500 psig we suggest the use of a sealant such as Locite Hydraulic Sealant Excessive torquing of metal fittings may cause a slight zero shift The use of plastic fittings typically results in no noticeable zero shift Torquing does not appreciably affect linearity or sensitivity 2 4 Venting Because the re...

Page 2: ...ative Model AXD Setra transducer 4 20 mA Power supply Load monitor _ _ _ CAUTION Reverse excitation will not cause damage to the unit unless voltage applied is above 50 VDC However the unit will not function if reverse wired Red Excitation Black Excitation Monitor or Control Device _ Green Out White Out Shield Out Out Model AXD Setra transducer Voltage Output Voltage Current output 3 2 Output wiri...

Page 3: ...sten the wires to terminals 3 Screw on the Model AXD top cover Hand tighten only 2Lb Ft 3N m max torque 4 Fit conduit into conduit fitting and tighten conduit liquid tight strain relief 3 4 EMC Certification This product complies with EN61326 electrical equipment for measurement control and laboratory use EMC requirements for minimum requirements and industrial locations Special caution should be ...

Page 4: ...ill repair or replace products found to be defective in materials or workmanship within the warranty period provided that a the product has not been subjected to abuse neglect accident incorrect wiring not our own improper installation or servicing or use in violation of instructions furnished by SETRA b the product has not been repaired or altered by anyone except SETRA or its authorized service ...

Reviews: