Before use of the luminaire, the protective foil on 
the front screen is to be removed.

For luminaires with integrated BATTERY

INFORMATION!

The battery is partly charged when delivered. 
Charging takes place after the commissioning of the 
luminaire. The full lighting duration is only available 
after it is fully charged. Please refer to the listed 
charging duration in the technical data.

Handling
By connecting the supply line to the supply network, 
the luminaire is in the operating state. For the con-
nection of further electric devices, the Schuko

®

 socket 

integrated in the cap is to be used.

INFORMATION!

The additional socket may differ from the version 
portrayed here in type and version.

ATTENTION!

Please implicitly consider the information for the 
socket (yellow label) which is located at the housing 
side in immediate proximity of the socket.

WARNING! Electrical current!

Connectors with IP67 have a bayonet system. For 
achieving the IP code, you will have to close the 
bayonet rings properly.
Generally, without properly closed bayonet rings, 
you only achieve IP44 (protection against splashing 
water and solid objects with at least 1mm).

Dimmable version
A button is integrated into the cap for the dimming. 
By pressing and holding of the button, the desired 
brightness is achieved. The adjusted value is retained 
after the luminaire is switched on / off.

Profiline LED36W 
MASTER / BATTERY / EMERGENCY LIGHT

Functionality
The versions with battery come with an integra-
ted emergency light feature. For the power grid 
operation, as well as the activation of the emergency 
light feature, the switch has to be in the ON (lower) 
position. In the case of a power failure, it switches to 
battery operation. Lighting duration and brightness in 
the battery mode are dependent on the version (see 
technical data).

When the switch is in the OFF position, the lighting 
function is deactivated, both in the normal and in the 
battery operation.

Charging of the battery takes place in the power grid 
operation and is independent from the switch posi-
tion. The ALDEBARAN

®

 Profiline LED with integrated 

battery has an emergency light feature. Through the 
emergency light feature, the luminaire is automati-
cally switched to battery operation in the case of a 
power failure if the luminaire is activated via the main 
switch (toggle switch). The luminaire can be turned 
on/off anytime via the main switch (toggle switch), 
however, the dimming feature is deactivated (not all 
versions).

When the power grid is back on, the luminaire is 
automatically switched back to mains operation. 
The battery is charged during power grid operation, 
regardless of the switch position of the main switch. 
In order to control the charge, there is an optical LED 
display which is located on the reflector (see picture).

Operation

Features

(Example)

Button

Summary of Contents for ALDEBARAN PROFILINE LED36W

Page 1: ...AUCHSANLEITUNG INSTRUCTIONS FOR USE InstructionS D UTILISATION PROFILINE SETOLITE Lichttechnik GmbH Bockhackerstr 13 42499 H ckeswagen Tel 49 0 21 92 9 36 24 0 Fax 49 0 21 92 9 36 24 25 E mail info se...

Page 2: ...Anwendungsbereich Inbetriebnahme Betrieb Dimmbare Ausf hrung Profiline LED36W MASTER AKKU NOTLICHT Dimmbare Ausf hrung mit Potentiometer Wartung und Instandsetzung Entsorgung R cknahme Technische Date...

Page 3: ...ise bei deren Nichtbeachtung die Gefahr einer Verletzung oder Lebensgefahr besteht VORSICHT Kennzeichnet Gefahren die Besch digungen des Ger tes zur Folge haben k nnen HINWEIS Hebt Tipps und andere n...

Page 4: ...Die Leuchte nicht bei hohen Umgebungs temperaturen ber 50 C betreiben Laden Sie den Akku nicht bei extrem hohen und niedrigen Temperaturen Die empfohlene Umgebungstemperatur liegt zwischen 10 30 C Bei...

Page 5: ...ers l sst sich die gew nschte Helligkeit einstellen Der eingestellte Wert bleibt nach Ein Ausschalten der Leuchte erhalten Profiline LED36W MASTER AKKU NOTLICHT Funktionsweise Bei den Versionen mit Ak...

Page 6: ...ehler m gl Ursache Behebung LEDs ohne Funktion Trennung vom Versorgungsnetz berpr fen Sie die Verbindung zum Netzan schluss Ausfall nur 1 LED Defekt einer LED Wenden Sie sich an Ihre Elektro fachkraft...

Page 7: ...us darf nur vom Kundendienst oder einer Elektrofachkraft vorgenommen werden Der Akku darf nur gegen ein Original Ersatzteil aus getauscht werden Bei Ger ten mit zwei Akkus immer gleiche Akkus mit glei...

Page 8: ...kg 4 3 kg Ersatzleuchtmittel Typ Leuchtmittel PL L 55W 840 4P Leuchtmittel PL L 80W 840 4P Artikelnummer 1410911014 1410937080 Aldebaran Profiline Serie LED Ausf hrung Typ LED 36W LED 54W Eingangsspa...

Page 9: ...tion Commissioning Operation Dimmable version Profiline LED36W MASTER BATTERY EMERGENCY LIGHT Dimmable version with potentiometer Maintenance and service Disposal returning Technical data Validity of...

Page 10: ...life WARNING Labels safety guidelines which can cause dangers of injuries or dangers of life when neglected ATTENTION Labels dangers that may lead to damages of the product INFORMATION Highlights tip...

Page 11: ...ans port regulations are to be respected valid for luminaires with Li Ion battery ALDEBARAN luminaires are applicable as indoor lighting and depending on the model and product also as outdoor lighting...

Page 12: ...e adjusted value is retained after the luminaire is switched on off Profiline LED36W MASTER BATTERY EMERGENCY LIGHT Functionality The versions with battery come with an integra ted emergency light fea...

Page 13: ...re Versions with LED Error Possible cause Solution LEDs without function Disconnected from supply mains Check the connection to the mains Failure of only 1 LED Defect of one LED Ask your trained elect...

Page 14: ...rried out by the customer support or a trained electrician The battery may only be replaced by an original replacement part When a device has two batteries always use identical batteries with the same...

Page 15: ...pe Illuminant PL L 55W 840 4P Illuminant PL L 80W 840 4P Item number 1410911014 1410937080 Aldebaran Profiline series LED edition Type LED 36W LED 54W Input voltage 100 240V AC 100 240V AC Power consu...

Page 16: ...on Mise en service Op ration Version r glable Profiline LED36W MASTER BATTERIE CLAIRAGE DE SECOURS Version r glable avec potentiom tre Nettoyage et entretien Gestion des d ch ts et reprise Donn es tec...

Page 17: ...ntifie des avertissements dont le non respect entra ne un risque de blessures voire la mort ATTENTION Indique les dangers auxquels des dommages sur l appareil peuvent donner suite INDICATION Attire l...

Page 18: ...des dommages la batterie Ne chargez pas la batterie des temp ra tures extr mement lev es ou basses La temp rature de stockage recommand e pour les batteries est de 10 30 C Des temp ratures froides peu...

Page 19: ...l e reste apr s avoir allum ou teind la lampe Profiline LED36W MASTER BATTERIE CLAIRAGE DE SECOURS Fonctionnement Dans les versions avec batterie on a r alis une lampe d clairage de secours Pour le fo...

Page 20: ...on Cause possible Suppression les LEDs ne fonc tionne pas D connexion du r seau d alimentation V rifiez la conne xion au secteur D faillance de seulement 1 LED Lampe d fecteuse Contactez un lectrotech...

Page 21: ...e doit tre remplac e que par une pi ce de rechange d origine Pour les appareils avec deux bat teries les piles doivent toujours tre install es avec les m mes batteries qui ont le m me tat de charge AT...

Page 22: ...7 kgs 4 3 kgs Lampe de rechange Type Source d clairage PL L 55W 840 4P Source d clairage PL L 55W 840 4P Num ro d article 1410911014 1410937080 S rie Aldebaran Profiline version LED Type LED 36W LED...

Page 23: ...Notizen Notes Remarques 23...

Page 24: ...micro film ou de traitement de donn es sont interdits sans l autorisation crite de l diteur Reproduction m me en partie interdite Cette notice est conforme l tat technique de l impression L volution...

Reviews: