13
SET Energietechnik Ltd. * August-Blessing-Str. 5 * D-71282 Hemmingen * Tel.: +49 (0)7150 9454-0 Fax: +49 (0)7150 2337
4. Transport / installation
4.1 Equipment transport
Please use only suitable aids for transport. Please observe health and safety
regulations and use your own personal protective equipment (gloves, safety shoes
etc.)
Only use loading equipment with sufficient load capacity;
Do not use damaged loading equipment;
Do not lay loading equipment on joints or sharp edges;
Use lifting trucks or cranes with sufficient load capacity;
Do not lift the load over persons;
For maintenance and repair work, use scaffolding or lifting platforms instead of ladders.
4.1.1 Equipment installation
The SET open-air swimming pool heat pump is a device for outdoor installation. A canopy or
an enclosure is, in principle, not necessary. The installation of the heat pump should be
carried out on a level and firm base. The clearance from buildings, walls or partitions should
be at least 1m on the air outlet side. On the air intake side, we recommend a clearance of at
least 0.5m to such obstacles.
In heating mode water comes out of the condensate pan of the heat pump. With the
enclosed hose connection, the water can be drained to seepage.
In heating mode, the heat pump blows out cold air on the fan, and hot air in cooling mode.
This area is not suitable for planting of any kind.
Important:
If the recommended clearances are not adhered to, worse efficiency of
the device is to be expected.
4.2 Electrical installation
For the connection values, please refer to the technical data or the type plate. Connection,
laying and protective measures of the on-site electrical installation must be implemented in
accordance with VDE regulation 0100. Please also observe the technical connection
conditions of the network operator of the local power networks. On the installation side, an
all-pole mains separator must be included with a contact opening width of at least 3mm per
pole (FI circuit breaker type B and back-up fuse (C) provided by the customer!) The device is
wired ready for connection. Regulation takes place with a protective low voltage of 12V.
Important:
Damage caused by incorrect or improper installation is not covered by
warranty.