3.
Technical data
3.3.2
Remote control
The optional remote control is designed for both surface- and flush-mounted installation. The
connection to the open-air swimming pool heat pump is via a two-wire bus line with a
maximum cross-section of 0.75mm².
M
Enter function menu. Also contains
the real-time parameters.
SET
Display or change the target value.
During programming, confirm a default
or display next parameter.
AUF
Arrow button
Selection of the display in the top
display:
Water
inlet/outlet
temperature
or
ambient temperature.
During
the
programming
phase,
increase
values
or
display
next
parameter.
AB
Arrow button
Selection of the display:
Outside air or defrost temperature.
During
the
programming
phase,
decrease values or display next
parameter.
Press and hold for 5 seconds to start
the chiller or heat pump operation.
Press and hold for 5 seconds to start
the heat pump operation or chiller.
3.3.3
Pool water pump
A pool water pump can be connected to terminals X1 1, N and PE on the terminal strip.
Please note the maximum switching capacity of 5 A.
3.4
Regulation
In the event of a deviation in the water temperature from the set target value, the fan and the
compressor will switch on. When the target value is reached, the heat pump will switch off.
All the necessary sensors and the low-water cut-off system are already built into the device.