24
Maintenance and care
: Trouble shooting
Loc
The message indicates that the unit is locked. If no buttons are pressed within 5
seconds the display will return to previous fail state.
Follow the steps below in order to unlock the unit.
Step Action
Description
1
UnLo
(unlock function) is displayed
2
tESt
(test function) is displayed
3
test is activated. The test will detect if the error is fixed.
• cccc
indicates that the error has been fixed and the unit is un-
locked successfully.
• faIL
indicates that the error is NOT fixed yet and the unit will
still be locked.
If the dehumidifier is not functioning correctly, shut it down immediately!
Use this table to understand the LED lights or localize and solve a possible problem/ fault:
Led
colour
Audible alarm Problem
Possible cause(s)
Solution
OFF
-
230V connected
but no function
Power outlet in wall is
disconnected
Restore the power
(Electrical)
-
Fuse F1 on main PCB
are blown
Replace the fuse
-
Defective power sup-
ply on main PCB
Replace main PCB
-
Disconnected/loose
230V connection
inside the unit
Check 230V con-
nections according
to wiring diagram
RED
(constant)
3 sec. initiating
beep
HP fault - Can’t
turn on /shuts
down
Defective fan
Replace fan
Dirty filter
Clean the filter
Dirty condenser coil
Clean coil
RED
(flashing)
Double beep
every 1 min.
LP fault - Can’t
turn on /shuts
down
Leaking refrigerant
Find leak and repair
leak + refill refriger-
ant
Malfunction of
thermostatic valve
Replace thermo-
static valve
Insufficient
refrigerant
Refill refrigerant
Single short
beep every 5
min.
Sensor fail -
check display
Defective sensor
Replace sensor
RED/
YELLOW
(flashing)
Single short
beep
Ambient tem-
perature out of
range
Ambient temperature
too high
Cool down the
room
Ambient temperature
too low
Heat up the room
Unlock Sequence
OK
OK
!
NOTICE
LED light and
troubleshooting
Summary of Contents for 1501 T
Page 1: ...SET 1501 T 2501 T 3501 T SERVICE MANUAL en Rev 1 0 2021 W12 3 ...
Page 2: ......
Page 30: ......
Page 31: ......