PROSWING(M)
Operating instruction
38
Fig. 36
DATA
PWF
GND
MASTER BOARD
SLAVE BOARD
Connection
selector
(optional)
Closing cycle will start only if both door have reached their own opening position. Re-opening after command or anti crus-
hing (even on only one door) will be on both doors.
Electric lock operation it is possible independently for each door.
Push & go: pushing one door will generate opening for both doors.
Anti crushing are independent for each door. Anti crushing in closing generates re-opening for both doors. Anti crushing in
opening stops only the door touched, the second one will open completely waiting for the other to finish its opening cycle.
ATTENTION:
Parameters modified through Millenniumware must be set separately on each control board.
2- In case of door with overlapping it is necessary to set displacement movement. Usually in opening a slight displacement
is enough, but in closing, where it is important to be sure to close on the right overlapping, an higher delay between the
two doors is needed.
If there is no overlapping:
set on MASTER parameter
21
=0 and parameter
22
=0;
If there is overlapping:
set on MASTER parameter
21
and parameter
22
more than 0
3- To set in function automatisms follow Start up paragraph procedure, considering that learning parameter (point 6 and 7)
has to be carried out only on Master door.
ATTENTION:
when learning procedure starts it opens first master door. It is necessary to stop the door in the max
opening desired point. Immediately after it starts opening the slave door and even for this door it is necessary to
stop the door in the max opening desired point. After this operation the doors will both start closing cycle (
CL
on
display blinking). When arrived in closed position
CL
stops blinking and door is ready to work.
Selector (optional) must be connected only on Master door. Parameters modified through selector will be changed both on
master and Slave door. (Fig. 36)