Operating logics
Operation
Description
LOW-ENERGY
In all operative procedures (except Stop Close) it is possible a motor opening with a reduced
speed (Low Energy speed) and higher idle time (idle time for disabled people) using the ope-
ning command for disabled [AUX IN 1set through parameters
15=0
(paragraph “Parameter
adjustment display”)]. The following closing is by spring.. The following closing is by spring.
PUSH & GO
An opening/closing automatic movement is possible by a manual moving of door that is in a clo-
sed position.
Set DIP 3 = ON.
SAFE CLOSE
If the safety sensors on the closing part of the door and connected to the control board on (Safe
Close) detects an obstacle whilst the door is closing, it will immediately stop and reverse the
motion of the door opening it completely at standard speed and then closing it at normal speed.
Detection of obstacles whilst the door is opening does not cause the system to react.
SAFE OPEN
If the safety sensor on the opening part of the door (Safe Open) detects an obstacle whilst the
door is opening, it will immediately stop the motion of the door. If the detenction stops, the door
will continue to open and then close at normal speed.
Detection of obstacles whilst the door is closing does not cause the reaction of the system.
If the door opens near a wall (in a corridor, for example) it is possible to cancel the final part of
opening in such a way sensor does not detect wall. This parameter is modificable through
parameter
20
(see paragraph “Parameter adjustment display”) or software MillenniumWare.
Operating logic
Manual
START 1 and START 2 are not monitored. Open and close only through push button on selec-
tor or low energy or manually pushing the door.
1 radar
Exit-only radar:
only the input START 2 of the electronic control card is monitored. A signal ori-
ginating from a sensor connected to this input triggers the opening and consequent closing of
the door doors. The electric locking system, if present, blocks the door doors every time that
these reach the position of complete closure
2 radar
Entry-exit radar
: both the inputs START1 and START2 of the electronic control card are moni-
tored. A signal originating from a sensor connected to one of these inputs triggers the opening
and consequent closing of the door doors.The electric locking system, if present, never blocks
the door doors.
Stop
Close
The automatism controls the complete closure of the door doors. In this logic the inputs START1
and START2 of the electronic control card are not monitored;if present, the electric locking
system blocks the door doors.
Stop
Open
The automatism controls the complete opening of the door doors.In this logic the inputs START1
and START2 of the electronic control card are not monitored.
Opening anti-crush
Whilst opening if door encounters an obstacle it stops movement for few seconds. After a while
door closes completely at low speed. Sensibility adjustable through parameter
06
(see para-
graph “Parameter adjustment display”) or software MillenniumWare.
Closing anti-crush
Whilst closing if door encounters an obstacle it stops, than opens completely at low speed. After
closes will be at slow speed. Sensibility adjustable through parameter
06
(see paragraph
“Parameter adjustment display”) or software MillenniumWare.
PROSWING(M)