background image

RAPID

 

BURNER

Injector  diam.(%mm)

Nominal

 

Rating

 

(kw)

Min.

 

Rating

 

(kw)

Consumption

 

in

 

1h

Consumption

 

in

 

1h

(at

 

15

0

C

 

and

 

1013mbar

 

press)

AUXILLARY

 

BURNER

Injector

 

diam.(%mm)

Nominal

 

Rating

 

(kw)

Min.

 

Rating

 

(kw)

Consumption

 

in

 

1h

Consumption

 

in

 

1h

(at

 

15

0

C

 

and

 

1013mbar

 

press)

MEDIUM

 

BURNER

Injector

 

diam.(%mm)

Nominal

 

Rating

 

(kw)

Min.

 

Rating

 

(kw)

Consumption

 

in

 

1h

Consumption

 

in

 

1h

(at

 

15

0

C

 

and

 

1013mbar

 

press)

LPG

G25

G30

28-30

  mbar

85

3

0.85

218.13

 

gr/h

50

1

0.4

72.71

 

gr/h

65

1.75

0.65

127.25

 

gr/h

G31

28-30/37

 

mbar

85

3

0.85

214.28

 

gr/h

50

1

0.4

71.42

 

gr/h

65

1.75

0.65

125

 

gr/h

58

1.75

0.65

127.25gr/h

43

1

0.5

72.71

 

gr/h

75

3

1.23

218.13

 

gr/h

G30

50

 

mbar

NG

G20

20

 

mbar

115

3

0.7

285.7

 

lt/h

72

1

0.3

95.24

 

lt/h

97

1.75

0.495

166.66

 

lt/h

25

 

mbar

125

3

0.82

332.2

 

lt/h

72

1

0.3

110.74

 

lt/h

94

1.75

0.495

193.79

 

lt/h

3

WOK BURNER

Injector diam.(%mm)
Nominal

 

Rating

 

(kw)

Min.

 

Rating

 

(kw)

Consumption

 

in

 

1h

Consumption

 

in

 

1h

(at

 

15

0

C

 

and

 

1013mbar

 

press)

96

3.6

1.6

271.7

 

gr/h

96

3.6

1.6

257.2 gr/h

 

76

3.6

2

261.7 gr/h

130

3.6

1.75

342.8

 

lt/h

1.40

3.6

1.6

398.7

 

lt/h

GAS CONSUMPTION TABLE

Summary of Contents for THG 46 VSS

Page 1: ...OPERATING AND INSTALLATION INSTRUCTIONS OF 60cm FRONT CONTROL BUILT IN GAS HOB THG 46 VSS...

Page 2: ...CONTENTS 1 DESCRIPTION OF THE HOB 2 SAFETY INSTRUCTIONS 3 INSTALLATION 4 USAGE 5 MAINTENANCE CARE...

Page 3: ...at is for the domestic cooking of foodstuffs Any other form of usage is to be considered as inappropriate and therefore dangerous The manufacturer declines all responsibility in the event of damage ca...

Page 4: ...2 1 DESCRIPTION OF THE HOB Control Knobs Wok Burner Auxillary Burner Medium Burner Pan Support Cooktop Medium Burner Ignition Button Rapid Burner...

Page 5: ...h 50 1 0 4 72 71 gr h 65 1 75 0 65 127 25 gr h G31 28 30 37 mbar 85 3 0 85 214 28 gr h 50 1 0 4 71 42 gr h 65 1 75 0 65 125 gr h 58 1 75 0 65 127 25gr h 43 1 0 5 72 71 gr h 75 3 1 23 218 13 gr h G30 5...

Page 6: ...the kitchen is well ventilated Keep natural ventilation holes open or install a mechanical ventilation device mechanical cooker hood Prolonged intensive use of the the appliance may call for addition...

Page 7: ...comply to current laws in force concerning ventilation and the evacuation of exhaust gases Always disconnect the gas supply from the appliance before carrying out any maintenance operations or repairs...

Page 8: ...could affect any third party or public liability insurances you may have VENTILATION REQUIREMENTS 2 3 For rooms with a volume of less than 5 m permanent ventilation of 100 mm free area will be require...

Page 9: ...ast 30 mm the cooker top must be kept no less than 100 mm away from any side wall Fig 3 2 Tthe cutout for the hob must be 35 mm from the rear wall there must be a distance of at least 750 mm between t...

Page 10: ...ening the screws B for the moment screw FASTENING THE COOKER TOP Insert the cooker top into the hole and position it correctly Fig 3 2 Adjust the position of the brackets A and tighten screws B to the...

Page 11: ...uct being installed or serviced and holding a valid certificate of competence for the work being carried out GAS CONNECTION The installation of the gas hob to Natural Gas or LP Gas must be carried out...

Page 12: ...s can be used where the sited ambient temperature of the hose does not exceed 70 C These hoses must be manufactured in accordance with local standards Gas hoses designed for natural gas MUSTNOTbe used...

Page 13: ...installed regulated and adapted to function with other types of gas by a QUALIFIED INSTALLATION ENGINEER 11 CHANGING THE GAS INLET During connection process the gas feeding manifold protruding from t...

Page 14: ...d The appliance must be installed in compliance with regulations in force Installation engineers must comply to current laws in force concerning ventilation and evacuation of exhaust gases Always unpl...

Page 15: ...gth is 4 5 mm in the min Position Fig 3 11 MINIMUM BURNER SETTING ADJUSTMENT Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to the minimum position If...

Page 16: ...tion diagrams strictly The protective earth connection PE must be connected to the terminal marked During installation please ensure that isolated cables are used Electrical Connection Before proceedi...

Page 17: ...ometime Continue pressing the ignition button until you see a stable flame on the burner Ignition Through Hob Valve microswitch Press the hob valve you want to operate and turn the valve in the counte...

Page 18: ...s and with a sufficiently thick base Ensure that the base of the pan is dry before placing it on the burners The temperature of accesible parts may be high when the appliance is operating So it is imp...

Page 19: ...issue Do not wash them while hot and never use abrasive powders or abrasive cleaning materials Do not leave vinegar coffee milk salt water lemon or tomato juice to remain in contact with enamelled par...

Page 20: ...r new product Even if you are familiar with domestic appliances please take a little time to read this booklet and familiarise yoruself with your new appliance Your safety is paramount installation ma...

Page 21: ...quipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate w...

Reviews: