LOCATION
The appliance may be installed in a kitchen, kitchen/diner or a bed sitting room,
but not in a room or space containing a bath or a shower.
3
The appliance must not be installed in a bed-sitting room of less than
20 m .
The appliance is designed and approved for domestic use only and should not be
installed in a commercial, semi commercial or communal environment. Your
product will not be guaranteed if installed in any of the above environments and
could affect any third party or public liability insurances you may have.
VENTILATION REQUIREMENTS
2
3
For rooms with a volume of less than
5 m -
permanent ventilation of
100 mm
free
area will be required.
3
3
For rooms with a volume of between
5 m
and
10 m
a permanent ventilation of
50
2
cm
free area will be required unless the room has a door which opens directly
the outside air in which case no permanent ventilation is required.
3
For rooms with a volume greater than
10 m -
no permanent ventilation is required.
NB. Regardless of room size, all rooms containing the appliance must have
direct access to the outside air via an openable window or equivalent.