background image

 

 

10

 

5.  Recommended reagents for vertical electrophoresis  

 

SERVA reagents for electrophoresis underly stringent quality and application control to 
ensure best performance and results. We recommend the usage of SERVA electro-
phoresis reagents especially along with Blue

Line

 electrophoresis instruments as the 

quality of consumables is fine-tuned to the equipment (application tests).  
 

Precast gels and Starter Kits 

SERVA

Gel

™ Gels for SDS PAGE 

Product 

Sample wells 

Cat. No. 

SERVA

Gel

™ TG PRiME™  Starter Kit 

 

43206 

SERVA

Gel

™ TG PRiME™ 8 % Tris-Glycine Gel 8 % 

12 

43260 

10 

43261 

SERVA

Gel

™ TG PRiME™ 10 % Tris-Glycine Gel 10 % 

12 

43263 

10 

43264 

SERVA

Gel

™ TG PRiME™ 12 % Tris-Glycine Gel 12 % 

12 

43266 

10 

43267 

2D 

43268 

SERVA

Gel

™ TG PRiME™ 14 % Tris-Glycine Gel 14 % 

12 

43269 

10 

43270 

2D 

43271 

SERVA

Gel

™ TG PRiME™ 4-12 % Tris-Glycine Gel 4-12 % 

12 

43273 

10 

43274 

SERVA

Gel

™ TG PRiME™ 4-20 % % Tris-Glycine Gel 4-20 % 

12 

43276 

10 

43277 

SERVA

Gel

™ TG PRiME™ 8-16 % % Tris-Glycine Gel 8-16 % 

12 

43279 

10 

43280 

2D 

43281 

SERVA

Gel

™ TG 8 % Tris-Glycine Gel 8 %

  

(Available upon request, please inquire.)

 

12 

43208 

10 

43209 

SERVA

Gel

™ TG 10 % Tris-Glycine Gel 10 %  

(Available upon request, please inquire.)

 

12 

43210 

10 

43211 

SERVA

Gel

™ TG 12 % Tris-Glycine Gel 12 % 

(Available upon request, please inquire.)

 

12 

43212 

10 

43213 

2D 

43226 

SERVA

Gel

™ TG 14 % Tris-Glycine Gel 14 % 

(Available upon request, please inquire.)

 

12 

43214 

10 

43215 

2D 

43227 

SERVA

Gel

™ TG 16 % Tris-Glycine Gel 16 % 

(Available upon request, please inquire.)

 

12 

43216 

10 

43217 

SERVA

Gel

™ TG 4-12 % Tris-Glycine Gel 4-12 % 

(Available upon request, please inquire.)

 

12 

43232 

10 

43238 

SERVA

Gel

™ TG 4-20 % % Tris-Glycine Gel 4-20 % 

(Available upon request, please inquire.)

 

12 

43230 

10 

43236 

SERVA

Gel

™ TG 8-16 % % Tris-Glycine Gel 8-16 % 

(Available upon request, please inquire.)

 

12 

43231 

10 

43237 

2D 

43228 

SERVA

Gel

™ Neutral pH 7.4  

12 

43220 

10 

43222 

SERVA

Gel

™ Neutral pH 7.4 Gradient 

12 

43221 

10 

43223 

SERVA

Gel

™ Neutral HSE Starter Kit 

12 

43207 

SERVA

Gel

™ Neutral HSE 

12 

43245 

10 

43246 

2D 

43247 

 

DOMINIQUE DUTSCHER SAS

Summary of Contents for BlueVertical PRIME

Page 1: ...STRUCTION MANUAL BlueVertical PRiME Vertical Electrophoresis Chamber SERVA Electrophoresis GmbH Carl Benz Str 7 D 69115 Heidelberg Phone 49 6221 138400 Fax 49 6221 1384010 e mail info serva de http ww...

Page 2: ...hat your expectations are reflected in the successful use of the apparatus First check that the apparatus has been received complete and undamaged following shipment Any faults or losses must be notif...

Page 3: ...ral care and maintenance 6 4 3 Gel and buffer volumes running conditions 6 4 4 Performing electrophoresis 7 4 4 1 Insertion of pre cast gel cassettes into the inner core running unit 7 4 4 2 Sample lo...

Page 4: ...nstruction All acrylic joints chemically bonded Doubly insulated cables rated safe up to 1000 volt Gold plated electrical connectors corrosion free and rated safe up to 1000 volt Safety lid with integ...

Page 5: ...removing the safety cover Do not attach the safety lid to the internal gel running unit while it is out of the bottom buffer chamber Do not exceed the maximum operating voltage or current see Table 1...

Page 6: ...ble1 The running conditions Table 2 vary according to the number of gels and their composition The current required will increase in proportion to the number of gels providing that the voltage is not...

Page 7: ...he precast gel cassette into the inner core running unit When running only one gel a dummy plate is required on the opposite side to retain the required buffer level Place the gel running unit into th...

Page 8: ...ctrophoresis Close the safety lid firmly making sure that the electrical connectors form a good contact Connect the electrophoresis apparatus to the power pack and connect the power pack to the mains...

Page 9: ...rode connectors with tissue Ensure that the connectors are clean and dry before usage or storage see chapter 4 2 For further information about the SERVA BlueLine please contact the technical service o...

Page 10: ...43277 SERVAGel TG PRiME 8 16 Tris Glycine Gel 8 16 12 43279 10 43280 2D 43281 SERVAGel TG 8 Tris Glycine Gel 8 Available upon request please inquire 12 43208 10 43209 SERVAGel TG 10 Tris Glycine Gel...

Page 11: ...DS Electrophoresis Buffer 20x 42560 Buffers for native PAGE SERVA Tris Glycine Native Sample Buffer 2x 42528 SERVA Tris Glycine Native Electrophoresis Buffer 10x 42530 Native Anode Buffer for BN CN 10...

Reviews:

Related manuals for BlueVertical PRIME