Control
35
Menus
Sub-Menu RESET
Reset to factory setting value.
Sub-Menu MAN TEST
How to enter the Sub-Menu MAN TEST:
You need to choose the " MAN TEST" on the main menu ( INFORMATION) And press the right button for 3
second .
Man test for installation
On sub-menu OPERATION---MAN TEST
ADD1 / 2 / 3 ON or OFF
ADD1 / 2 / 3 ( electrical heater 1 / 2 /3 )
3 WAY
ON or OFF
3-WAY VALVE
4 WAY
ON or OFF
4-WAY VALVE
WARM PUMP
ON or OFF
WATER PUMP
OUT FAN
ON or OFF
OUTDOOR FAN
This menu is for installation engineer, user operation is prohibitive. The testing function will dissolve as
soon as the menu is off the interface.
ADD 1
3 WAY
4 WAY
WARM PUMP
MAN TEST
OFF
OFF
OFF
OFF
OUT FAN
OFF
P.S : the compressor only runs 5 minutes for testing, at that time its frequency is 45Hz.
CMP
OFF
CMP
ON or OFF
COMPRESSOR
ADD 2
OFF
ADD 3
OFF
Sub-Menu
LANGUAGE
LANGUANG
ENGLISH
FRENCH
LANGUAGE
Language selection :
How to enter the Sub-Menu of LANGUAGE:
You need to choose the "LANGUAGE" on the
Main menu ( INFORMATION ).
Press the right button.
Then " LANGUAGE" menu can be seen.
Use Up and Down botton to select the language ,
and press Right button to confirm.