22
Control
General information
Control Panel
The control panel of DC inverter series features a graphic display, five control buttons.
Functions
The control computer is operated with the help of a user friendly menu system that is displayed on the control
panel. There is a main menu and several sub-menus accessible from the main menu. The menus are
described in detail further down.
To be able to select the desired menu and increase or reduce preset values, you will use the five buttons.
•
One button pointing upwards marked with a up arrow
•
One button pointing downwards marked with a down arrow
•
One button pointing to the right marked with a right arrow
•
One button pointing to the left marked with a left arrow
•
One button pointing to the ON/OFF
Operating Instructions
General Information
Menu Navigation
The right-hand button on the control panel is used to open the desired menu.
The left-hand button is used to return to the previous menu.
The up and down buttons are used to navigate between the parameters of a menu.
A cursor (arrow) on the left-hand side of the display indicates which menu can be opened.
The up and down buttons are also used if you wish to increase or reduce a preset value.
Display of current operating mode
During normal operation, the following information will be displayed:
• Desired (preset) room temperature
• Date / time / timer
• Whether there is a heating demand or not. If there is, there will also be symbols telling which heat source is
working, heat pump or auxiliary heater or both (see ”Symbols”).
• Which operating mode has been selected.
When display at the interface, press button Right and Left at the same time for 5 seconds
to lock the display. All buttons are not available after lock is active, until press button Right
and Left at the same time for 5 seconds to open the lock
ROOM 20
MONDAY
11:30
1
HDO
CSP
95
%
ROOM 20
MONDAY
11:30
1
HDO
CSP
95
%
OPER.WARMWATER
OPER.WARMWATER
•The running speed percentage of compressor.