Serene S2044 ROMA Space Heater 

 

 

 

Positioning 

This heater is water resistant to IP24. It can therefore be used in 
bathrooms or other areas subject to humidity, The heater must be 
installed so that switches and other controls cannot be touched by a 
person in the bath or shower. 

The heater must be mounted on the wall, with a minimum height of 
300mm above the floor or any other objects heated below it, and a 
minimum distance of 400mm below the ceiling and from adjacent walls. 
The heater must not be located immediately below a socket outlet. 

Ensure that the heater is not mounted in a situation where the heated 
air is directed over an open door, curtains, or any towel rail, creating a 
fire risk. Leave at least 1 metre of space in front of the heater to allow 
correct air delivery. 

The heater must be mounted a minimum distance of: 

  300mm above floor level or any other objects heated below it 

  400mm below the ceiling and from adjacent walls 

Ceiling 

Floor 

 

Wall 

 

400mm 

Min. 

400mm 

Min. 

300mm 

Min. 

400mm 

Min. 

Wall 

 