7

The dual glass module is designed for clamp installation. It need the clamps 
with rubber strips to fix on the bracket. Figure 1 and figure 2 show the structure 
of two kind of clamps.

Figure 1 Double-side clamp

Table 1 Components of the clamp

NO.

Name

Remark

Aluminium alloy

6063-T5

Spring

Bolt

M8 stainless steel bolt

Rubber strip

Ethylene Propylene 

*OKTK36*3ͨ

1

2

3

4

Figure 2 Single-side clamp

INSTALLATION GUIDE FOR SERAPHIM 

DUAL GLASS PHOTOVOLTAIC MODULE

INSTALLATION GUIDE FOR SERAPHIM 

DUAL GLASS PHOTOVOLTAIC MODULE

-0$"5*0/"/%"/(-&4&-&$5*0/

(&/&3"-*/45"--"5*0/13*/$*1-&

• Module can be installed in both landscape and portrait modes

1

• The clamp shall not shade the front side of the cells.

• The PV modules shall be installed high enough to keep it away from potential 
shading, flying sands, snow and water.

• It is recommended to install the PV modules 30cm away from the ground to make 

sure ventilation. 

• Appropriate installation structures shall be chosen to meet required mechanical 
load. 

• It is recommended to install the PV modules with minimum angle of 10 degree to 
make the dust easily to be washed off. 

• It is recommended to keep minimum 2cm gap between PV modules for thermal 

expansion of materials.

• Install PV modules appropriately according to corresponding mechanical load 
need.

It is recommended to install PV modules where has excellent sunlight resources. In 

the Northern Hemisphere, the module should typically face south, and in the 

Southern Hemisphere, the modules should typically face north. The most optimistic 
installation angle varies according to different latitudes and longitudes; please con

-

sult experts with appropriate knowledge background when determining the instal

-

lation locations and angles.

When choosing a site, avoid trees, buildings or obstructions, which could cast 

shadows on the solar photovoltaic modules. Shading causes hotspot and loss of 
output, even though the factory fitted bypass diodes of the PV module will mini

-

mize such effect. 

Do not install the PV module near naked flame or flammable materials. 

Do not install the PV module in a location where it would be immersed in water or 

constantly exposed to water from a sprinkler or fountain etc. 

• It is recommended to install the bifacial modules 1m away from the ground or roof 
to maintain the energy yield of module rear side.

In order to ensure that the modules can withstand a downward force of up to 

2400 Pa (244 kg/m2), the modules shall be fixed on the bracket with the long 

side of the module, using a minimum of four clamps. Please make sure to use at 
least of two purlins behind the modules to support the modules.

The selection and installation of the clamps shall obey the requirement accord

-

ing to table 2. Otherwise the module may not satisfy the mechanical load and 

-

have the risk of broken.

The applied torque should be big enough to fix it steadily.The reference torque 
for screw  

1

4

2

2

1

4

is 16~20N*m. 

Summary of Contents for SRP 6MA-BG Series

Page 1: ...PHOTOVOLTAIC MODULE JIANGSU SERAPHIM PHOTOVOLTAIC SYSTEM CO LTD ADDRESS JIANGSU CITY OF CHANGZHOU PROVINCE WANG ZHEN HENG ROAD NO 1 2 TELEPHONE 86 519 68788166 FAX 86 519 88786181 MAILBOX info seraphi...

Page 2: ...lers should assume all risks of injury that might occur during installation including but not limited to the risk of electric shock One single PV module may generate more than 30V DC when exposed to d...

Page 3: ...including wires and cables connectors charging regulators inverters storage batteries recharge able batteries etc Under normal outdoor conditions the current and voltage generated will differ from tho...

Page 4: ...sunlight resources In the Northern Hemisphere the module should typically face south and in the Southern Hemisphere the modules should typically face north The most optimistic installation angle varie...

Page 5: ...ithstand a downward force of up to 5400 Pa 550 kg m2 the modules shall be fixed on the bracket with the long side of the module using a minimum of four clamps Please make sure to use at least of two p...

Page 6: ...xed on the bracket with the long side of the module using a minimum of four screws Please make sure to use at least of two purlins behind the modules to support the modules The selection and installat...

Page 7: ...stem voltage the Voc temperature coefficient feature and the extreme low temperature of installation location must be taken into consideration when calculate the Voc of the PV string The PV modules co...

Page 8: ...ny problem arises consult a professional for suggestions Caution observe the maintenance instructions for all components used in the system such as support frames charging regulators inverters batteri...

Page 9: ...eet any of the following conditions 1 When the DC side input terminal of the inverter or combiner box is original MC4 2 When the manufacturer of inverter or combiner box requires series DC input bus t...

Reviews: