• Do not apply paint or adhesive to the PV module top surface.
• Do not use PV modules with broken glass which has danger of electrical shock.
• Do not handle panels in wet condition unless has appropriate protection.
• Do not expose PV module to sunlight until installation to avoid unnecessary deg-
radation.
• Installation shall be in conformity with IEC standard, Safety Standard for Electrical
Installations.
• Do not disconnect under load.
• Do not touch conductive parts of PV modules, such as terminals which can result
in burns, sparks and lethal shock whether or not the PV module is connected.
• Do not touch the PV module unnecessarily during installation.
• Do not work in the rain, snow or windy conditions.
• Do not expose the artificially sunlight to PV modules. Completely cover the PV
module with an opaque material during installation to prevent electricity from
being generated.
• Do not drill holes on the modules of broke the encapsulation on the module
side.
• Do not wear metallic rings, watchbands, ear, nose, lip rings or other metallic
objects while installing or troubleshooting.
• Only use insulated tools that are qualified for working on electrical installations.
• Follow the safety regulations for all other system components, including wires
and cables, connectors, charging regulators, inverters, storage batteries, recharge-
able batteries, etc.
• Under normal outdoor conditions the current and voltage generated will differ
from those listed on the datasheet. When design systems, current and short-circuit
current should be multiplied by a factor of 1.25 to determine components ratings.
• Only use connectors compatible with the PV module connectors. Removing the
connectors without prior authorization will invalidate the warranty.
• Do not dismantle installed modules to another project, which may invalidate the
warranty.
Each module has two Barcode stickers which have the same unique serial No. of
each module and one label sticker:
Barcode 1: Laminated into PV modules.
Barcode 2: Stick on the backside of PV modules.
Label: Stick on the backside of PV modules, contains characteristics parameters of
the PV modules.
Check the serial No. in the barcode with the packing list when unpacking. Provide
PV module serial No. when you need support from SERAPHIM on particular PV
modules.
• The fire rating of this module is valid only this Guide is followed.
• Consult your local authority for Guidelines and requirements for building or
structural fire safety.
• Do not use PV modules near equipment or in places where flammable gases
may be generated.
• Follow local codes and laws when install the modules