PROVISIONAL MOTOR INSTALLATION
13-Close the gate completely. Provisionally fix the rear
bracket - Fig. 12 - onto the gate post by welding or by
means of plugs, observing distances B and
C. Provisionally fix the motor to the rear bracket using
the central hole. As shown in Fig. 12
143-Move the motor up against the closed leaf to deter-
mine the front bracket welding point. Move the motor
away from the leaf.
Provisionally fix the front bracket to the gate, obser-
ving the distance and travel limits of the mobile pin.
Insert the mobile pin on the bushing and the latter on
the front bracket - Fig. 13 A - then provisionally secure
by means of the nut and washer.
15-Ensure that the motor is levelled. - Fig. 14 -
16-Release the motor - Fig. 15 - using the special key fi-
xed to the terminal board cover. Check that movement
is smooth - Fig. 16 -. Return the gate to the closed po-
sition and block the motor using the special key fixed
to the terminal board cover - Fig. 15 -.
FINAL INSTALLATION
17-Remove the motor from the brackets. Weld the front
bracket in its final position.
Fix the rear bracket in its
final position. - Fig. 17 -
18-Refit the motor. Any differences in values B and C can
be compensated for using the 5 holes on the rear brac-
ket. - Fig. 12 -
19-Refit the upper casing, keeping the front section
slightly inclined to engage the connector tooth and then
lower and secure by means of the rear screw.
- Fig. 18-
20-Reclose the rear cover and remove the safety key.
- Fig. 19 and 20 -
Fig. 12
FRONT BRACKET
Fig. 13
REAR
BRACKET
Fig. 17
Fig. 14
!!
Bracket
Bushing
Washer
Nut
Fig. 20
Fig. 19
Fig. 18
1
2
Fig. 13 A
Fig. 16
Fig. 15
SIN
CE
1
96
5