PROVISIONAL MOTOR INSTALLATION

13-Close the gate completely. Provisionally fix the rear 

bracket - Fig. 12 - onto the gate post by welding or by 
means of plugs, observing distances B and 
C. Provisionally fix the motor to the rear bracket using 
the central hole. As shown in Fig. 12 

143-Move the motor up against the closed leaf to deter-

mine the front bracket welding point. Move the motor 
away from the leaf.
Provisionally fix the front bracket to the gate, obser-
ving the distance and travel limits of the mobile pin.
Insert the mobile pin on the bushing and the latter on 
the front bracket - Fig. 13 A - then provisionally secure 
by means of the nut and washer.

15-Ensure that the motor is levelled. - Fig. 14 -

16-Release the motor - Fig. 15 - using the special key fi-

xed to the terminal board cover. Check that movement 
is smooth - Fig. 16   -. Return the gate to the closed po-
sition and block the motor using the special key fixed 
to the terminal board cover - Fig. 15 -.

FINAL INSTALLATION

17-Remove the motor from the brackets. Weld the front 

bracket in its final position.

 Fix the rear bracket in its 

final position. - Fig. 17 -

 

18-Refit the motor. Any differences in values B and C can 

be compensated for using the 5 holes on the rear brac-
ket. - Fig. 12 -

19-Refit the upper casing, keeping the front section 

slightly inclined to engage the connector tooth and then 
lower and secure by means of the rear screw. 
 - Fig. 18-

20-Reclose the rear cover and remove the safety key. 

- Fig. 19 and 20 -