Advice for wiring up in non-specialised environments.
1. Fit an omnipolar switch upstream of the system, choosing one with a gap of at least 3mm between the contacts. Or,
alternatively, use a 10A thermal magnetic circuit breaker switch.
2. Make all types of connection with the system disconnected from the power, i.e. with the main switch set to OFF
(symbol “0”). The control unit, in particular, must never be connected to the power supply either during the wiring up,
or when fitting any expansion cards.
3. The following cables must be used for installation of the system:
2
2
- for the motor power supplies: 4x1.5mm version 230V,
2x2,5mm
version 24V
,
2
- for the battery and electric lock power supplies: minimum 2.5 mm
2
2
- for the control unit power supplies: 1.5mm section for lengths of up to 19m, 2.5mm section for lengths of up to
31m,
2
2
- for the flashing light: 0.75mm section for lengths of up to 3m, 1.5mm section for lengths of up to 19m,
- for the low voltage and current lines, (e.g. for the photocells, control buttons, electromechanical key, sensitive
2
2
edges and other safety devices: 0.5mm section for lengths of up to 50m, 0.75mm section for lengths of up to
100m.
!
WARNING: never make sharp bends in the
cable on exit from the motors - Fig. 10 - as
this may cause damage and constitute a
hazard over time.
12- Refit the terminal board cover.
11- Remove the terminal board cover and proceed with elec-
trical connections. - Fig. 11 -
10- Refit the lower casing by securing the screws
|
__
_
_
Fig. 10
NO
YES
Terminal board cover
|
__
_
_
COM A/C A/C 1 2 3
WARNING:
On versions MT/B4 - at 230V~ - the capacitor
is pre-wired internally.
FOR MOTOR 230V~
2
Use a cable of 4x1,5mm with the sequence:
Earth connection (MT/B4 only)
COM MT/B4 motor common
A/C
MT/B4 open/close
A/C
MT/B4 open/close
FOR MOTOR MT/C4 24Vdc
2
Use a cable of
2x2,5mm
with the sequence:
2
MT/C4 open/close
3
MT/C4 open/close