3.12 Utilities
If not agreed otherwise in the contract conditions, the
sera
multi-layer diaphragm pump will always be supplied with the
necessary utilities.
(For type and quantitiy of utilities/lubricants, see Chapter 11)
4
Transportation and intermediate storage
4.1
General
Before shipment
sera
products are tested for proper
functioning and quality.
An undamaged packaging protects the device during subse-
quent storage and should only be opened when the multi-layer
diaphragm pump will be installed.
CAUTION !
The packaging material must be disposed of
appropriately!
4.2
Transport
Select a hoist which is adapted to the weight of the pump and
attach it to the motor flange of the pump (see Fig. 02).
Fig. 02 Transport/Handling
4.3
Storage
An undamaged packaging protects the device during
subsequent storage and should only be opened when the
multi-layer diaphragm pump will be installed.
A proper storage will increase the service life of the pump.
Proper storage means avoidance of negative influences, such
as heat, humidity, dust, chemicals etc.
The following storage conditions must be observed:
•
Storage place: cool, dry, dust-free and slightly ventilated.
•
Storage temperature between +2°C and + 40°C.
•
Humidity not more than 50%.
•
The maximum storage time for the standard system is 12
months.
If this value is exceeded, products made from metal should be
sealed in foil and protected against condensation water using
suitable desiccants.
Do not store solvents, fuels, lubricants, chemicals, acids,
disinfectants and similar together with the product in the
storage room.