CHAPTER 3. CONF
I
GUR
I
NG THE ASTERX SB3
3.1.4 Connecting via COM
I
n case you do not have an appropriate USB cable, Ethernet cable or a LAN network available,
you may still connect to the receiver using one of the receiver
’
s COM ports and RxControl.
Step 1: Connect the Power and COM cables
Connect the COM cable to the connector labeled
’
COM-GP
I
O
’
on the rear panel of the receiver
as shown in Figure 3-6 and connect the other end to a computer.
I
t may be necessary to use
a serial-to-USB converter. Now connect the power cable to the receiver and make sure the
correct input voltage is applied (between 4.5 and 36 V DC).
Figure 3-6:
Rear panel COM 1 socket
Step 2: Open RxControl and connect to the AsteRx SB3
Once connected, open RxControl on the computer to which the receiver is connected and
follow the sequence of steps described in Figure 3-7 to open a connection to the AsteRx SB3
. Note that RxControl is part of the RxTools software suite which can be freely downloaded
from the Septentrio website.
Figure 3-7:
Connecting to the receiver via COM using RxControl. Select
’
Serial
Connection
’
and choose
’
Create New
’
. Next, choose the correct serial port, de
fi
ne a
name for the connection and press Finish.
12
Summary of Contents for AsteRx SB3
Page 1: ...AsteRx SB3 User Manual ...