background image

5

SentrySafe UL Type 1 Electronic Lock        ProStaff UL Type 1 Electronic Lock

1.

Using two hands, hold the keypad, thumbs down, on its left and right sides. Push up the keypad
with your thumbs and disconnect it from the safe by pulling it towards you. (Fig.A)

2.

Let the disengaged keypad hang by its wires. This will expose the battery holder.  

3.

Fasten battery to connector on back side of keypad and insert battery into back of keypad. (Fig.B)

4.

Reconnect the keypad by positioning slots over tabs and slide down.

Opening the lock

(See back cover of this manual for the generic code. This code was set by the factory
for all Type 1 locks, and it is recommended that you change it immediately upon
receipt of your safe.)

NOTE:  The lock allows 10 seconds for each key press. If you pause longer, the lock

will not respond, indicating you should start over.

1.

Press the six-digit generic code. The lock responds with a “double beep” and the red LED flashes.

2.

Turn handle clockwise and open the door.

NOTE: Three beeps indicate an incorrect code has been entered. Wait 30 seconds and

enter correct code

.

Programming your own unique user code

(Always perform this with door open.)

1.

Enter “zero” six times.

2.

Enter the existing 6-digit generic code (1,2,3,4,5,6).

3.

Enter your NEW 6-digit user code two times.

4.

If a mistake is made, wait 30 seconds and repeat steps 1 – 3.

5.

Test lock operation several times before closing door.

Valid Code Entry

– Double signal after valid 6-digit code is entered. 

Invalid Code Entry

– Triple signal and old code is still valid.

Keep your new user code secure

For your records, please copy it here: 

______  ______  ______   ______   ______    ______    

Delay mode

The lock automatically enters a 5-minute delay mode after an invalid code has been entered four
consecutive times. At the end of the delay period, two more consecutive invalid codes will restart an
additional five minute delay period.

Battery replacement

When old battery is removed for replacement, your User Code will still work.

Low battery warning

Repeated beeping during an opening indicates that the battery is low and needs 
immediate replacement.

Lost user code   

To gain access in the event of a lost user code, first, find your safe’s Serial Number. The Serial
Number is printed on the small label on the right side of the safe (outside). Send this and a check
or money order for $12.00 (U.S. funds). Please include a written statement of ownership witnessed
and signed by a notary public or bank official. The notary must have a different last name than the
owner. Mail to: Sentry Group, Dept. 200, 882 Linden Avenue, Rochester, NY  14625-2784, USA, or fax
statement (notary seal must be legible) to 1-585-381-2940. Payment may also be made using your
VISA or Mastercard credit card by phone only. Call 1-800-828-1438 to make credit card payment. Do
not fax credit card information. 

*

NOTE: Prices subject to change without prior notification.

SentrySafe and ProStaff Fire-Safe gun safes

See the chart below to determine the fire rating for your safe model. 

Fire ratings

To be sure your safe performs as rated and complies with its ratings, remove it from the pallet
before installation.

ETL verified fire claim

Verified by ETL SEMKO to meet manufacturer’s specification for fire resistance 1200°F (649°C) or
1400°F (760°C) for 30 minutes endurance. 

Lifetime after-fire replacement guarantee

If a SentrySafe or ProStaff Fire-Safe product is damaged by fire at any time while still owned by you
(the original owner), Sentry Group will ship a replacement free of charge, if you send the following
to Sentry Group, 882 Linden Avenue, Rochester, NY 14625-2784 USA:
• Your name and address;
• A description of the fire, with the model number, serial number and a photo of the burned unit,

and a copy of the report from the fire department, insurance or police.

A

B

B

A

Fire Ratings

ETL 1200°F (649°C) - 30          ETL 1400°F (760°C) - 30

SentrySafe Models

GV8526, GX1852, GX8599

ES5251, ET8523 

GXW2252H, GXW2252H-S
GT8423, GT8523

ProStaff by

GPT1852, GPT1855G, GPT2245G

SentrySafe Models

GPT2255G, GPW1842H, GPW1852H
GPW2242H, GPW2252H

Do not store your safe on the pallet on which it was shipped. SentrySafe or ProStaff
Fire-Safe gun safes which are ETL-tested and verified, will not comply with their 
ratings if the safe is stored on the shipping pallet.

Summary of Contents for ProStaff

Page 1: ...GUN SAFE EXECUTIVE SAFE OWNER S MANUAL MANUEL DE L UILISATEUR COFFRE FORT D ARMES À FEU DE DIRECTION MANUAL DEL PROPIETARIO CAJA FUERTE PARA ARMAS DE FUEGO CAJA FUERTE EJECUTIVA ...

Page 2: ...without help Before attempting to unbolt your new safe be certain someone is with you to help steady the safe while you work Ensure the safe is standing upright on a flat level surface Fig A NOTA Sentry Group is not responsible for any costs incurred for unit to be removed from pallet and installed in place Tools equipment required Adjustable wrench pliers or 17 mm 11 16 socket wrench Hammer Instr...

Page 3: ...T clockwise pass the second number of the combination two times and stop on the second number the third time 4 Change directions again Turning LEFT counterclockwise pass the third number of the combination once and then continue around in the same direction stop on the third number of the combination 5 Change directions again turning RIGHT until the dial stops completely and will not move 6 Turn s...

Page 4: ...reen Proceed LED single beep occurs 1 After entering each digit of Factory or User Code or User PIN 2 After pressing Clear key 3 After pressing Program key Green LED only 1 Comes ON after you enter a valid code User PIN and remains lit during the 4 second period in which the safe can be opened 2 Comes ON in the Program User Code mode after you enter the Factory Code and remains lit until you have ...

Page 5: ...g indicates that the battery is low and needs immediate replacement Lost user code To gain access in the event of a lost user code first find your safe s Serial Number The Serial Number is printed on the small label on the right side of the safe outside Send this and a check or money order for 12 00 U S funds Please include a written statement of ownership witnessed and signed by a notary public o...

Page 6: ... 14625 2784 U S A Do not ship your product back to Sentry Group The Sentry Group Customer Service Department will decide either to have the product returned repaired replaced or refund your money Proof of Purchase Date For all Sentry Group products a dated store receipt is required as proof of purchase Limitations Of Warranty 1 Sentry s responsibility and the buyer s exclusive remedy under this wa...

Page 7: ...u pour faire passer les boulons à tra vers le fond du coffre fort 3 Fermez la porte et mettez la poignée dans sa position de verrouillage 4 Demandez à l autre personne de vous aider à faire glisser le coffre fort vers un bord de la palette Faites basculer le coffre fort jusqu à ce que l un de ses côtés touche le sol fig C 5 Retirez la palette et remettez le coffre fort à la verticale sur le sol In...

Page 8: ...le en haut au centre de la roue est essentiel pour faire fonctionner votre combinaison avec succès Composez votre combinaison lentement et en faisantattention pour éviter de passer au delà des numéros désirés Pour le cas où votre roue dépasserait le bon chiffre il vous serait nécessaire d entrer à nouveau la combinaison entière Enfin d éviter de causer des dommages au mécanisme de la serrure ne fa...

Page 9: ...code ne peut pas être effacé Mais si vous préférez utiliser votre propre code vous pouvez programmer le coffre fort de telle sorte qu il s ouvre lorsque vous composez le Code Usager à 5 chiffres de votre choix Si vous voulez permettre à quelqu un d avoir temporairement accès au coffre fort vous pouvez programmer un NIP Usager qu il vous sera possible d effacer plus tard Comment programmer une code...

Page 10: ...eux ans ou lorsque la DEL jaune reste allumée Mode retardé La serrure entre automatiquement en mode retardé de deux minutes lorsqu un code invalide a été composé trois fois de suite Dans ce mode la serrure ne peut pas être activée et l introduction de tout chiffre déclenchera un signal d ERREUR Clés égarées ou combinaisons oubliées Commencez par rechercher le numéro de série de votre coffre fort C...

Page 11: ...un notaire ou par un membre de la direction d une banque Le notaire doit avoir un nom de famille différent de celui du propriétaire Adressez à Sentry Group Dept 200 882 Linden Avenue Rochester NY 14625 2784 États Unis or fax statement notary seal must be legible to 585 381 2940 Le paiement peut également être effectué à l aide de votre carte de crédit VISA ou Mastercard par téléphone uniquement Ca...

Page 12: ...s de garantie 1 La responsabilité de Sentry et le recours exclusif de l acheteur aux termes de cette garantie sont limités à la réparation ou au remplacement au choix de Sentry de la des pièce s défectueuse s ou du produit En aucun cas Sentry ne sera tenu responsable de tout dommage indirect ou consécutif incluant sans toutefois s y limiter les pertes ou dommages dus aux incendies à l eau au vol o...

Page 13: ...y o con pinzas mientras gire las tuercas 2 Una vez que esten quitadas las tuercas utilice un martillo para sacar los pernos a través de la parte inferior de la caja fuerte 3 Cierre la puerta y coloque la manija en posición cerrada 4 Con la ayuda de su asistente deslice la caja fuerte a una orilla de la tarima Voltee la caja fuerte de manera que la orilla se mueva hacia el suelo Fig C 5 Quite la ta...

Page 14: ...cero a menos que los pasadores se encuentren en la posición cerrada con la manija en posición vertical El uso correcto de la cerradura con combinación dependerá en gran medida de la correcta alineación de la cerradura con la guía de apertura la línea vertical arriba del centro del indicador numérico Marque la combinación lenta y cuidadosamente sin pasarse de los números deseados Si se pasa de los ...

Page 15: ...úmero de identificación personal Siempre puede abrir la caja fuerte introduciendo el código de fábrica de 5 dígitos Este código no puede ser borrado Pero si prefiere emplear su propio código puede programar la caja para que se abra con el código de usuario de 5 dígitos que usted seleccione Si desea dar a alguien acceso tem poral a la caja fuerte puede programar un NIP de usuario que puede borrarse...

Page 16: ...ión perdidas Primero localize el número de serie de su caja fuerte El Número de Serie se encuentra impreso en la pequeña etiqueta del lado derecho afuera de la caja fuerte Envíe éste y un cheque u órden de pago por 12 00 Moneda de E U A 12 00 Dólares E U A para llaves y 12 00 Dólares E U A para combinaciones Por favor incluya una carta notarizada con testigos y firmada por un notario público u ofi...

Page 17: ... notarizada con testigos y firmada por un notario público u oficial bancario declarando que usted es el propietario El notario deberá tener un apellido diferente al del propietario Envíe por correo postal a Sentry Group Dept 200 882 Linden Avenue Rochester NY 14625 2784 USA o envíe su reclamación por fax sello del notario deberá estar visible al 1 585 381 2940 El pago se pue de efectuar con tarjet...

Page 18: ...código de acceso antes de marcar el número 800 Es un proceso de 2 pasos Paso 1 marque 08 800 288 2872 o 001 800 462 4240 Paso 2 a la indicación marque 1 800 451 0821 O por escrito a Sentry Group 882 Linden Avenue Rochester New York 14625 2784 U S A No envíe su producto a Sentry Group El Departamento de Servicio al Cliente de Sentry Group decidirá si el producto se devolverá se reparará se reemplaz...

Page 19: ...19 ...

Page 20: ...a para retocar llame al Departamento de Servicio al Cliente indicado abajo Verde Negro Verde Medianoche Cereza Negra Serial No N de série No de serie Combination Combinaison Combinación Serial No N de série No de serie Factory Code Code de fabricant Código de fábrica 3 Number Combination Lock Verrou à Combinaison de 3 Chiffres Cerradura de Combinación de 3 Números Serial No N de série No de serie ...

Reviews: