background image

W2XT

THERMOCOUPLE TRANSMITTER

(PC programmable)

MODEL

W2XT

INSTRUCTION MANUAL

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System’s Sales Office or representatives.

 PACKAGE INCLUDES:

  Signal conditioner (body + CJC Sensor) ...................... (1)

 MODEL NO.

Confirm  Model  No.  marking  on  the  product  to  be  exactly 
what you ordered.

 INSTRUCTION MANUAL

This  manual  describes  necessary  points  of  caution  when 
you use this product, including installation, connection and 
basic maintenance procedures.
The unit is programmable using the PC Configurator Soft-
ware.    For  detailed  information  on  the  PC  configuration, 
refer to the W2CFG users manual.  The W2CFG PC Con-
figurator Software is downloadable at M-System’s web site: 
http://www.m-system.co.jp.

POINTS OF CAUTION

 POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

  100 – 240V AC rating: 85 – 264V, 47 – 66 Hz, approx. 5 – 7VA
  24V DC rating: 24V ±10%, approx. 3W

 GENERAL PRECAUTIONS

• Before you remove the unit from its base socket or mount 

it, turn off the power supply and input signal for safety.

 ENVIRONMENT

• Indoor use
• When heavy dust or metal particles are present in the air, 

install the unit inside proper housing with sufficient ven-
tilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -5 to +55°C     

(23 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Be sure that the ventilation slits are not covered with ca-

bles, etc.

 WIRING

• Do  not  install  cables  (power  supply,  input  and  output) 

close  to  noise  sources  (relay  drive  cable,  high  frequency 
line, etc.).

• Do  not  bind  these  cables  together  with  those  in  which 

noises are present.  Do not install them in the same duct.

 AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 20 minutes is required for 
satisfying  complete  performance  described  in  the  data 
sheet.

• With  voltage  output,  do  not  leave  the  output  terminals 

shortcircuited  for  an  extended  time  period.   The  unit  is 
designed to endure it without breakdown, however, it may 
shorten appropriate life duration.

COMPONENT IDENTIFICATION

Fixing Screw

Connection
Diagram

Specifications

Body

Base Socket

DIN Rail
35mm wide

Spring Loaded
DIN Rail Adaptor

INSTALLATION

Loosen the fixing screw at the front of the unit in order to 
separate the body from the base socket.

 DIN RAIL MOUNTING

Set the base socket so that 
its  DIN  rail  adaptor  is  at 
the  bottom.    Position  the 
upper hook at the rear side 
of  base  socket  on  the  DIN 
rail and push in the lower.  
When removing the socket, 
push  down  the  DIN  rail 
adaptor  utilizing  a  minus 
screwdriver and pull.

 WALL MOUNTING

Refer  to  the  external  di-
mensions.

CJC Sensor

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-SYSTEM Mini-MW Series

Page 1: ...e 10 10 V DC V3 Range 5 5 V DC Configurator software is used to change output over the described range of the selected suffix code For changing between suffix codes set the Output Range Selector on th...

Page 2: ...0 2000 C N N 0 1000 C U U 0 300 C L L 0 500 C P Platinel II 0 1200 C OUTPUT SPECIFICATIONS DC Current Operational range 0 23 mA DC Minimum span 1 mA Offset Lower range can be any specific value withi...

Page 3: ...20 20 20 20 20 20 20 20 20 20 20 20 20 0 to 1760 150 to 1370 170 to 1000 180 to 1200 170 to 400 400 to 1760 200 to 1760 0 to 1760 0 to 2315 130 to 1300 200 to 600 200 to 900 0 to 1395 THERMO COUPLE M...

Page 4: ...MENSIONS unit mm inch 4 8 7 10 23 91 89 3 50 84 3 31 10 39 22 87 59 2 32 DIN RAIL 35mm wide 4 16 11 M3 SCREW 72 2 83 29 5 1 16 53 2 09 2 4 2x5 17x 20 MTG HOLE 6 24 deep 114 4 49 11 5 6 1 2 3 9 6 23 Wh...

Page 5: ...2nd output option DIP SW DIP SW Base Socket 1 Low Drift Amplifier Burnout 2 4 Digital Computation CONFIGURATOR JACK STATUS 5 9 T C CJC SENSOR metal leg model CJM comp leadwire Specifications are subj...

Page 6: ...s vibration Do not subject the unit to physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 30 to 90 RH in order to ensure adequate life span an...

Page 7: ...OFF ON 1 2 3 4 Provided only for two output type CHECKING 1 Terminal wiring Check that all cables are correctly con nected according to the connection diagram 2 Check DIP switch setting 3 Power input...

Page 8: ...D2 LD3 indicate the transmitter s operating status by different flashing pat terns Examples are shown below LD1 LD2 LD3 A LD1 LD2 LD3 G LD1 LD2 LD3 R NORMAL OPERATION RUN MODE ERROR MODE Parameter Err...

Page 9: ...with a copy of its original sales invoice THIS IS THE ONLY WARRANTY APPLICABLE TO M SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHA...

Reviews: