background image

MODEL: W2XT

EXTERNAL VIEW

LED1 (LD1)

LED2 (LD2)

LED3 (LD3)

Configurator Jack

■ 

FRONT VIEW

■ 

SIDE VIEW

SW1

SW2

Output 2

Configuration DIP SW

Output 1

Configuration DIP SW

OFF

ON

1 2 3 4

OFF

ON

1 2 3 4

*

Provided only for two-output type.

*

Refer to the instruction manual for detailed procedures.

DIMENSIONS unit: mm (inch)

4

8 7

10

23 (.91)

89 (3.50)

84 (3.31)

10 (.39)

22 (.87)

59 (2.32)

DIN RAIL
35mm wide

[4 (.16)]

11

M3

SCREW

72 (2.83)

29.5 (1.16)

53 (2.09)

2

4.2x5

(.17x.20)

MTG HOLE

6 (.24) deep

114 (4.49)

11

5

6

1

2

3

9

6 (.23)

 When mounting, no extra space is needed between units.

(.16)

TERMINAL ASSIGNMENTS

1

6

8 7

10

11

3

9

4

2

1

5

CJC SENSOR
(model: CJM)

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-SYSTEM Mini-MW Series

Page 1: ...e 10 10 V DC V3 Range 5 5 V DC Configurator software is used to change output over the described range of the selected suffix code For changing between suffix codes set the Output Range Selector on th...

Page 2: ...0 2000 C N N 0 1000 C U U 0 300 C L L 0 500 C P Platinel II 0 1200 C OUTPUT SPECIFICATIONS DC Current Operational range 0 23 mA DC Minimum span 1 mA Offset Lower range can be any specific value withi...

Page 3: ...20 20 20 20 20 20 20 20 20 20 20 20 20 0 to 1760 150 to 1370 170 to 1000 180 to 1200 170 to 400 400 to 1760 200 to 1760 0 to 1760 0 to 2315 130 to 1300 200 to 600 200 to 900 0 to 1395 THERMO COUPLE M...

Page 4: ...MENSIONS unit mm inch 4 8 7 10 23 91 89 3 50 84 3 31 10 39 22 87 59 2 32 DIN RAIL 35mm wide 4 16 11 M3 SCREW 72 2 83 29 5 1 16 53 2 09 2 4 2x5 17x 20 MTG HOLE 6 24 deep 114 4 49 11 5 6 1 2 3 9 6 23 Wh...

Page 5: ...2nd output option DIP SW DIP SW Base Socket 1 Low Drift Amplifier Burnout 2 4 Digital Computation CONFIGURATOR JACK STATUS 5 9 T C CJC SENSOR metal leg model CJM comp leadwire Specifications are subj...

Page 6: ...s vibration Do not subject the unit to physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 30 to 90 RH in order to ensure adequate life span an...

Page 7: ...OFF ON 1 2 3 4 Provided only for two output type CHECKING 1 Terminal wiring Check that all cables are correctly con nected according to the connection diagram 2 Check DIP switch setting 3 Power input...

Page 8: ...D2 LD3 indicate the transmitter s operating status by different flashing pat terns Examples are shown below LD1 LD2 LD3 A LD1 LD2 LD3 G LD1 LD2 LD3 R NORMAL OPERATION RUN MODE ERROR MODE Parameter Err...

Page 9: ...with a copy of its original sales invoice THIS IS THE ONLY WARRANTY APPLICABLE TO M SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHA...

Reviews: