GENERAL SPECIFICATIONS

Construction: Plug-in
Connection: M3 screw terminals (torque 0.8 N·m)
Housing material: Flame-resistant resin (black)
Isolation: Input to output 1 to output 2 to power
Overrange output: -15 to +115 %
(Negative current output is not available.)
Zero adjustment: -5 to +5 % (PC programming)
Span adjustment: 95 to 105 % (PC programming)
Burnout: Upscale standard; downscale, specific value output
or no burnout optional by programming
Linearization: Standard
Cold junction compensation: CJC sensor attached to the
input terminals
Status indicator LED: Tri-color (green/amber/red) LED;
Flashing patterns indicate operation status of the
transmitter.
Programming: Downloaded from PC; input type and range,
output type and range, zero and span, burnout type, user’s
linearization table, etc.
For detailed information, refer to the users manual for the
PC configurator.
Configurator connection: 2.5 dia. miniature jack;
RS-232-C level

INPUT SPECIFICATIONS

Input resistance: 1 MΩ min.
Burnout sensing: ≤ 4 μA
If not specified, the input range is shown below.
1 PR: 0–1600°C
2 K: 0–1000°C
3 E: 0–500°C
4 J: 0–500°C
5 T: 0–300°C
6 B: 500–1600°C
7 R: 500–1600°C
8 S: 0–1600°C
9 C (WRe 5-26): 0–2000°C
N N: 0–1000°C
U U: 0–300°C
L L: 0–500°C
P Platinel II: 0–1200°C

OUTPUT SPECIFICATIONS

■ DC Current
Operational range: 0 – 23 mA DC
Minimum span: 1 mA
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
Load resistance: Output drive 12 V max. for Output 1; 7 V
max. for Output 2
(e.g. 4 – 20 mA: 600 Ω [12 V/20 mA])
If not specified, the output range is 4 – 20 mA DC.
■ DC Voltage
Code V2 (wide spans)
  Operational range: -11.5 – +11.5 V DC
  Minimum span: 1 V
Code V3 (narrow spans)
  Operational range: -6 – +6 V DC
  Minimum span: 0.5 V
Offset: Lower range can be any specific value within the
output range provided that the minimum span is
maintained.
Load resistance: Output drive 1 mA max.
 (e.g. 1 – 5 V: 5000 Ω [5 V/1 mA])
If not specified, the output range is shown below.
V2: 0 – 10 V DC
V3: 1 – 5 V DC

INSTALLATION

Power Consumption
•AC:
 Approx. 5 VA at 100 V
 Approx. 6 VA at 200 V
 Approx. 7 VA at 240 V
•DC: Approx. 3 W
Operating temperature: -5 to +55°C (23 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Mounting: Surface or DIN rail
Weight: 150 g (0.33 lbs)

PERFORMANCE in percentage of span

Overall accuracy: Input ac output accuracy
• Input accuracy: Accuracy (Table 1) + Cold Junction
Compensation Error 3°C (5.4°F)
• Output accuracy: Max. Output Range / Span × ±0.04%
Cold junction compensation error:
±3°C at 25 ±10°C
±5.4°F at 77 ±18°F
Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) of max. span
Response time: ≤ 1 sec. (0 – 90 %)
Burnout response: ≤ 10 sec.
Line voltage effect: ±0.1 % over voltage range

Rugghölzli 2
CH - 5453 Busslingen

Tel. +41 (0)56 222 38 18

Fax +41 (0)56 222 10 12

[email protected]

www.sentronic.com

Produkte, Support und Service

SENTRONIC

AG

Summary of Contents for M-SYSTEM Mini-MW Series

Page 1: ...e 10 10 V DC V3 Range 5 5 V DC Configurator software is used to change output over the described range of the selected suffix code For changing between suffix codes set the Output Range Selector on th...

Page 2: ...0 2000 C N N 0 1000 C U U 0 300 C L L 0 500 C P Platinel II 0 1200 C OUTPUT SPECIFICATIONS DC Current Operational range 0 23 mA DC Minimum span 1 mA Offset Lower range can be any specific value withi...

Page 3: ...20 20 20 20 20 20 20 20 20 20 20 20 20 0 to 1760 150 to 1370 170 to 1000 180 to 1200 170 to 400 400 to 1760 200 to 1760 0 to 1760 0 to 2315 130 to 1300 200 to 600 200 to 900 0 to 1395 THERMO COUPLE M...

Page 4: ...MENSIONS unit mm inch 4 8 7 10 23 91 89 3 50 84 3 31 10 39 22 87 59 2 32 DIN RAIL 35mm wide 4 16 11 M3 SCREW 72 2 83 29 5 1 16 53 2 09 2 4 2x5 17x 20 MTG HOLE 6 24 deep 114 4 49 11 5 6 1 2 3 9 6 23 Wh...

Page 5: ...2nd output option DIP SW DIP SW Base Socket 1 Low Drift Amplifier Burnout 2 4 Digital Computation CONFIGURATOR JACK STATUS 5 9 T C CJC SENSOR metal leg model CJM comp leadwire Specifications are subj...

Page 6: ...s vibration Do not subject the unit to physical impact Environmental temperature must be within 5 to 55 C 23 to 131 F with relative humidity within 30 to 90 RH in order to ensure adequate life span an...

Page 7: ...OFF ON 1 2 3 4 Provided only for two output type CHECKING 1 Terminal wiring Check that all cables are correctly con nected according to the connection diagram 2 Check DIP switch setting 3 Power input...

Page 8: ...D2 LD3 indicate the transmitter s operating status by different flashing pat terns Examples are shown below LD1 LD2 LD3 A LD1 LD2 LD3 G LD1 LD2 LD3 R NORMAL OPERATION RUN MODE ERROR MODE Parameter Err...

Page 9: ...with a copy of its original sales invoice THIS IS THE ONLY WARRANTY APPLICABLE TO M SYSTEM PRODUCT AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHA...

Reviews: