background image

ZEGGO TTX_N1Z2 

REV. 1, 12/17 

 

 

Future Integrated Data Evaluation 

 

Wireless Temperature 

Transmitter (External Probe) 

 

Model: TTX_N1Z2 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       USER MANUAL     

 

 

Summary of Contents for TTX N1Z2

Page 1: ...ZEGGO TTX_N1Z2 REV 1 12 17 1 Future Integrated Data Evaluation Wireless Temperature Transmitter External Probe Model TTX_N1Z2 USER MANUAL ...

Page 2: ...ZEGGO TTX_N1Z2 REV 1 12 17 2 DOCUMENT HISTORY Release No Date Revision Description 1 14 12 17 First Release Temperature Transmitter TTX_N1Z2 V1 0 2 16 04 19 System manual updated 3 4 5 6 7 ...

Page 3: ...Secure AES128 IEEE802 15 4 Radio Transmission to Zeggo s Gateway Easy Configuration and Installation 2 Years of Battery Life Internal storage to store during network failure Programmable sampling interval 1min 5min 10min 15min 30min Specification Battery 3 6V 4400mAh lithium battery AA size Battery Life 6 months to 3 Years Depending on environment condition and transmission time setting Innoflex i...

Page 4: ...our of status LED will indicate current ON OFF status Table 1 Turn On And Off Operation Button Press and Hold Period Status LED Behaviour ON OFF Status 3 second Flashing of Green LED Turn ON 5 second Light up Red LED Turn OFF Go into Sleep A signal will send out to the gateway immediately after turned on accompany with blinking of LED indicating the operation status Green LED indicated the data re...

Page 5: ...ensor to the device to ensure measurement accuracy Configuration Binding Sending Interval Setting Device will enter configuration mode from special sequence button press and hold i Make sure the device is in OFF state and wait for about 4 second ii Press the ON OFF configuration button for 4 times Interval must less than 2 secs iii Press and hold the button for the 5th attempt The status LED will ...

Page 6: ...tting has been set leave it for about 10 seconds to exit the configuration mode The device will back into OFF state It will bind to nearest gateway and follows the transmission interval setting after turned ON after startup cycle finished Internal Memory Backup In the event when signal failed to send to a gateway the temperature data stores in the internal memory These backup data will send again ...

Page 7: ...iew from Zeggo s portal It is recommended to replace the battery if battery level is less than 20 The suggested signal percentage for a stable connection is 40 to take care the moving object or addition of object in between signal path Information Regarding Product Disposal This product contains Lithium Thionyl Chloride Battery There are a fire explosion and severe burn hazard Do not burn or expos...

Page 8: ...LOSS OF GOODWILL LOSS OF REVENUE OR PROFIT FAILURE OF OTHER EQUIPMENT TO WHICH PRODUCT IS CONNECTED WITH RESULTING FROM THE SUE OF PRODUCT RELATING TO WARRANTY SERVICE OR ARISING OUT OF ANY BEACH OF THIS LIMITED WARRANTY EVEN IF FLEX GLOBAL INNOVATIONS PTE LTD HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES THE SOLE REMEDY FOR A BREACH OF THE FOREGOING LIMITED WARRANTY IS REPAIR REPLACEMENT OR...

Reviews: