Specifications
AS-11C User Manual
10.Specifications
10.1 Data sheet
Table 10.1 Data Sheet
Function parameter
Minimum value
Typical value
Maximum
Scanning angle range
360°
Scanning angle
0°
360°
Scanning angle
resolution
0.5°
Scanning frequency
12.5Hz
Target reflectivity
3%
1000%
(
Reflector
)
Measuring range
0.1m
20m
18% reflectivity range
20m
10% reflectivity range
15m
Measurement delay
1
0ms
80ms
160ms
Measurement error
System error
±5cm(1m~15m)
±12cm(1m~15m)
Statistical error
(
1σ
)
±2cm(1m~15m)
±4cm(1m~15m)
Temperature drift
0cm/
℃
0.4cm/
℃
Power-on start delay
25s
27s
30s
Area monitoring function
Monitoring mode
Point Monitoring / Target Width Monitoring / Contour Monitoring
Number of regional
groups
16
Number of concurrent
work area groups
1
16
TCP response delay
2
10ms
100ms
190ms
I/O response delay
3
10ms
90ms
170ms
General parameters
Min value
Typical value
Max. value
Laser transmitter
Pulsed laser diode
Laser wavelength
895nm
905nm
915nm
Laser Level
Class 1
(
GB 7247.1-2012
,
Eye safety
)
Laser outlet caliber
10mm
Laser divergence angle
9.6(H)
╳
1.8(V)mrad
10.0(H)
╳
2.0(V)
mrad
11.0(H)
╳
2.5(V)
mrad
Distance from emission
45mm
056 222 38 18
www.sentronic.com
SENTRONIC
AG