51
Device installation
AS-11C User Manual
5.2.2 Height and angle adjustment when multiple LiDARs work simultaneously
If there are multiple laser lidar working at the same time in the use environment, the
laser emitted by one laser lidar should be prevented from being directly incident into the
light-transmitting cover of another laser lidar, otherwise, the measurement of the two
laser lidars may be interfered with each other, and false measurement data may appear
at their respective specific scanning angles.If there is such a possibility, the laser scanning
surface height or pitch angle of the lidar should be adjusted to avoid mutual interference,
as shown in "Figure 5.2 Scanning surface height adjustment" and "Figure 5.3 Scanning
surface pitch angle adjustment".
Figure 5.2 height adjustment of scanning surface
Figure 5.3 Pitching angle adjustment of scanning surface
Important Tips
If the above installation and adjustment cannot be
achieved, you can try to power off and re-energize the lidar
that caused the erroneous measurement until the erroneous
measurement data disappears. Once the erroneous
measurement disappears, it will not reappear in a short time.