Contents
AS-11C User Manual
V.1
056 222 38 18
[email protected]
www.sentronic.com
SENTRONIC
AG
Page 1: ...Contents AS 11C User Manual V 1 056 222 38 18 mailbox sentronic com www sentronic com SENTRONICAG...
Page 2: ...28V Power consumption 3 8W DC24V Outer covering protection range IP65 GB 4208 2008 Weight 0 5Kg Dimensions L W H 86 85 59 mm Working temperature range 10 45 Storage temperature range 30 70 Ambient ill...
Page 3: ...Figure 2 2 power socket The power supply voltage is required to be DC12V 28V under normal operation the power consumption is 3 8W and the maximum power consumption is 4 3W Please provide power accordi...
Page 4: ...st Table 3 1 Product deliverables list Deliverables qty unit Description User Manual 1 piece Certificate 1 piece Warranty Card 1 piece AS 11C 1 piece Laser LiDAR AS 11C AT 1 pair Simple bracket AS 11C...
Page 5: ...emperature range Distance measurement Pulsed flight time measurement technology system 905nm infrared laser measurement class 1 safety laser GB 7247 1 2012 human eye safety The maximum range is 20 met...
Page 6: ...arming and forced alarms via I O input terminals Monitor the signal through the I O output terminal and Ethernet TCP message output area No PC configuration is supported Availability Reliability Anti...
Page 7: ...The AS 11C has a built in area monitoring function which is mainly used for indoor AGV obstacle avoidance and other Movement applications It can also be used for indoor security protection which can a...
Page 8: ...negative end TX Data reception positive end TX Data receiving negative end I O interface IN1 Universal input 1 positive end IN2 Universal input 2 positive en IN3 Universal input 3 positive end IN4 Un...
Page 9: ...light transmitting cover The dirt of the AS 11C s light transmitting cover will cause a decrease in the light transmitting performance When the transmittance drops to 60 the measurement capability may...
Page 10: ...al size of the light spot r0 is the exit diameter of the light spot for AS 11C r0 0 01m H is the horizontal divergence angle of the light spot forAS 11C H 0 01 V is the vertical divergence angle of th...
Page 11: ...h other At this time the measurement will be inaccurate and a pseudo edge point farther than the actual distance of the target edge will be generated As shown in Figure 4 2 Pseudo edge point the diffe...
Page 12: ...gure 4 3 Figure 4 3 Mirror measurement 4 1 5 Transparent media When there is a transparent medium such as clean water in the surrounding environment targets inside or behind the medium can be detected...
Page 13: ...ect and hit other targets on the reflected optical path All these echoes may form a complex overlapping relationship based on the length of actual optical path resulting in uncertain measurement resul...
Page 14: ...group the custom regional group is a polygon group drawn manually by the user using the custom regional group function of FILPS and the edge can be fine tuned after drawing Related Reading For the ed...
Page 15: ...on Table 4 3 Basic parameters of preset area groups Parameter Setting Value Description Radius of the shielding zone 20cm The minimum radius of the shielding zone at short distance Targets smaller tha...
Page 16: ...sponse threshold a monitoring signal is output Attenti on pre wa rning alarm Target s width cm 6 Existence time Scan ning cycle 0 Contour monitoring Check the integrity and stability of the background...
Page 17: ...ers the monitoring area at a specific position and specific shape is detected and the normal target contour database is generated based on the accumulated normal target contour measurement data as sho...
Page 18: ...becomes invalid Main Point After the device is ready you can read the status of the I O terminal through TCP messages or control the output status of the OUT port The effective output status and hold...
Page 19: ...e of the AS 11C and the installation height as shown in Figure 5 1 the relationship between the effective working distance and the installation height Taking the horizontal floor installation as an ex...
Page 20: ...here is such a possibility the laser scanning surface height or pitch angle of the lidar should be adjusted to avoid mutual interference as shown in Figure 5 2 Scanning surface height adjustment and F...
Page 21: ...scanning range You can use the FILPS software to adjust the scan start angle and scan end angle of the AS 11C as follows Use FILPS to connect AS 11C through Ethernet to configure the device configura...
Page 22: ...the newly set working scan range parameters come into effect At this time the AS 11C only outputs the measurement data within the working scan range and the area monitoring function only processes th...
Page 23: ...55 Device installation AS 11C User Manual Figure 5 8 Effective scanning range adjustment software operation interface 056 222 38 18 mailbox sentronic com www sentronic com SENTRONICAG...
Page 24: ...t Ref GND Level Figure 6 2 I O Interface Input Terminal External Circuit Floating In the connection mode of the input terminal in the above figure the voltage of the external signal power supply must...
Page 25: ...ent configuration and commissioning test AS 11C User Manual Figure 7 1 Online device form Figure 7 2 Device window and device configuration tab 056 222 38 18 mailbox sentronic com www sentronic com SE...
Page 26: ...serves the output result of the output end of the I O interface of AS 11C and can also test the forced control function disarm force alarm through the external switch Open the running status tab in th...
Page 27: ...4cm 1m 15m Temperature drift 0cm 0 4cm Power on start delay 25s 27s 30s Area monitoring function Monitoring mode Point Monitoring Target Width Monitoring Contour Monitoring Number of regional groups 1...
Page 28: ...008 Class 2 Electromagnetic field radiation immunity GB T17626 3 2006 Class 2 Surge immunity GB T17626 5 2008 Power interface 1 2 50us 2KV 1KA Class 3 Ethernet interface 10 700us 1KV 25A Class 2 I O i...
Page 29: ...ng Dimension4 Length 86mm Width 85mm Height 59mm Interface cable length 1M Weight 0 5Kg Electrical parameters Min value Typical value Max value Measuring power Type DC power supply Supply voltage 12V...
Page 30: ...74 Specifications AS 11C User Manual 10 3 Equipment outline drawings Figure 10 2 Equipment outline drawing 056 222 38 18 mailbox sentronic com www sentronic com SENTRONICAG...
Page 31: ...5 Specifications AS 11C User Manual 10 4 Accessories outline drawings Figure 10 3 AS 11C AT side mounting outline and assembly drawing 056 222 38 18 mailbox sentronic com www sentronic com SENTRONICAG...