WORLD OF WELLNESS
2. Connection
All the individual modules are connected via data cables; here there is a difference between
the 4-pin data cables (RJ10) and the 6-pin data cables (RJ12). The RJ12 cables are used
to connect the individual power supply units and the touch operating unit to one another
and the RJ10 cables are used for the interior operating units. The following wave.com4
modules are available and can be used with the touch operating unit:
●
wave.com4 sauna
●
wave.com4 infra
●
wave.com4 sound&light
Important:
If just the wave.com4 sauna and wave.com4 sound&light are being used,
the
WC4-SL-EXT
extension cable set must be ordered.
Once all the components have been connected, the power supply units need to be pre
-
pared for use with the touch unit.
wave.com4 Touch
wave.com4 Infra
RJ12
RJ12
RJ12
wave.com4
sound&light
wave.com4
Sauna
RJ12
Innenbedienteil
Sauna
RJ10
Innenbedienteil
sound&light
RJ10
Connection example for complete con-
figuration with 2 interior operating units:
Connection example without wave.com4 infra:
JPBM
wave.com4 sauna
Attach the
JPBM
jumper wire to the sauna power supply unit. This jumper wire is included
in the delivery scope of the touch operating unit.
WC4-SL-EXT
RJ10
RJ12
wave.com4 Touch
wave.com4
sound&light
wave.com4
Sauna
RJ12
RJ12