background image

4

.2.3 CNT Mod

e

se

t to 

US

D by d

e

fault. To chang

e

 th

e

 cu

rren

cy, p

ress

 th

e

               k

e

y, us

e

 th

e

 a

rr

ow k

e

y

s

  

to highlight the d

e

si

re

d cu

rren

cy, th

en

 p

ress

 the               k

e

y.

Figure 4-5 

S

DC Mod

e

Figure 4-7 CNT Mod

e

4.3 Currency Op�ons 

In CNT mode, the counter will only count the number of bills, and it does not track the 

denomina�on of the bills or the currency. NOTE: while using CNT mode, counterfeit 

detec�on is disabled. In this mode, the counter has three available coun�ng speeds - 

800, 1000, or 1200 bills per minute.

While the counter is powered on, a flag and 3-digit currency code will appear in the 

top le� corner of the display, indica�ng the current currency se�ng. The currency is 

Figure 4-6 SDC Mode a�er coun�ng

Figure 4-8 CNT Mode a�er coun�ng

Summary of Contents for SB-1200

Page 1: ......

Page 2: ...Sen nel SB 1200 User Manual...

Page 3: ...on Keys 06 3 3 Display Interface 07 4 0 Opera ng Instruc ons 08 4 1 Start up 08 4 2 Coun ng Mode 09 4 2 1 MDC Mode 09 4 2 2 SDC Mode 09 4 2 3 CNT Mode 10 4 3 Currency Op ons 10 4 3 1 Automa c Currency...

Page 4: ...5 1 3 Clean the Feed Gap 17 5 1 4 Clean the Stacker Sensors 18 5 2 Cleaning the Internal Sensors 18 5 2 1 Open the Back Cover 19 5 2 2 Open the Internal Cover 19 5 2 3 Clean the Lower CIS Bar and UV...

Page 5: ...inter Port USB Port External Display Port Power Cord Jack Figure 1 2 Back Diagram Figure 1 1 Front Diagram 1 0 Machine Overview Control Panel Impeller Stacker Bill Guide Display Back Cover Power Switc...

Page 6: ...Bill Feeding Hopper Handle Wheel Feed Gap Screw Figure 1 4 Side Diagram Figure 1 3 Top Diagram...

Page 7: ...ontents Bill Guides Cleaning Brush Cleaning Cloth Spare Fuse User Manual 2 0 Unpacking and Installa on Sen nel SB 1200 1 1 1 1 1 1 1 1 2 Item Name Picture Quan ty Pcs Calibra on Card Power Cable Exter...

Page 8: ...lla onandUseLoca on Figure 2 1 Installa on and use loca on As shown in gure 2 1 please keep clear of surrounding walls and reserve su cient space for opera on and maintenance Installa onSpace Maintena...

Page 9: ...nector 2 3 1 Safety Precau ons 2 3 Installa on Intruc ons 1 This machine is designed speci cally for indoor use Do not install or use outdoors 2 Place machine on a at and stable surface 3 Do not use o...

Page 10: ...l 3 0 Control Panel and Display Print Key Print your count results Report Key Review your count results 3 2 Func on Keys Auto Manual Key Toggle between automa c start and manual start SNC Key Ac vate...

Page 11: ...on o Coun ng mode CFD level Coun ng speed Selected currency Auto start on o Numberof billscounted Valueof billscounted 3 3 Display Interface Mode Key Select coun ng mode hold to set CFD level Batch Ke...

Page 12: ...creen A erconnec ngthemachinetoapowersource ipthepowerswitchtotheonposi on Themachinewillperformabriefself check whichtakesabout20seconds Themachinewillspinthebanknoteprocessingwheelsseveral mesbefore...

Page 13: ...de the counter has two available coun ng speeds 800 or 1000 bills per minute In SDC mode the counter will count a single denomina on of the selected currency recording both the total value of the bill...

Page 14: ...f bills and it does not track the denomina on of the bills or the currency NOTE while using CNT mode counterfeit detec on is disabled In this mode the counter has three available coun ng speeds 800 10...

Page 15: ...e corner of the display and the machine will count all denomina ons of the currency All other currencies will be rejected 4 3 2 Mul currency Coun ng When the currency is set to MULT the machine can co...

Page 16: ...r If automa c start is disabled the machine will not start coun ng un l you press the START key Automa c Start is on by default and can be enabled or disabled by pressing the AUTO key Figure 4 13 Batc...

Page 17: ...three op ons 800 1000 and 1200 The default coun ng speed for all three coun ng modes is 1000 The coun ng speed can be changed by pressing the SPEED key The batch quan ty can be changed by pressing th...

Page 18: ...counted as well as a breakdown of each denomina on counted Press the BACK key to return to the main count screen If serial number capture was enabled during the count you can view the serial numbers...

Page 19: ...ons NOTE Se ng the CFD level to zero will disable counterfeit detec on en rely If the machine is connected to a printer the count details can be printed A er performing a count press the PRINT key to...

Page 20: ...maintain op mal opera on of your bill counter Circulated bills collect dust dirt and grime that can impair the opera on of your bill counter s sensors and feeding system Any dirt or dust stuck to the...

Page 21: ...gure 5 2 clean the bill feeding wheel with a nylon brush or cleaning cloth 5 1 3 Clean the Feed Gap As shown in Figure 5 3 clean the feed gap with a nylon brush Figure 5 2 Bill Feeding Wheel Figure 5...

Page 22: ...h or cleaning cloth Stacker Sensor Stacker Sensor 5 2 Cleaning the Internal Sensors Figure 5 4 Stacker Sensors Open the back cover to access and clean the internal sensors NOTE Please move the power s...

Page 23: ...Back Cover As shown in Figure 5 5 open the back cover 5 2 2 Open the Internal Cover As shown in Figure 5 6 open the internal cover Press the handle down rmly to release the internal cover Figure 5 5...

Page 24: ...ylon brush 5 2 4 Clean the Upper CIS Bar As shown in Figure 5 8 clean the upper CIS bar with a cleaning cloth 5 3 Bill Jams Figure 5 7 Lower Sensors Figure 5 8 Upper CIS Bar In the event a bill gets s...

Page 25: ...ap as described in sec on 5 4 3 Damaged Bill the jammed bill was defec ve in one way or another as shown in Figure 5 10 It is not recommended to count damaged bills 5 4 Feed Gap Calibra on A properly...

Page 26: ...e gap between the rollers as shown in Figure 5 14 The gaps between rollers Fine tune the feed gap as follows Turn the feed gap screw clockwise to make the feed gap wider and counterclockwise to make t...

Page 27: ...he feed gap screw clockwise to open the gap wider 4 If the bill ts loosely into the gap or you can t more than one bill at once this means the feed gap is set too wide Rotate the feed gap screw counte...

Page 28: ...erfeit Detec on USD CAD MXN EUR GBP CHF COP and CRC 800 1000 pcs min MDC SDC MODE 800 1000 1200 pcs min CNT MODE only 50 110 90 190 mm 0 075 0 15 mm AC 100V 240V 50 60Hz 500 bills 200 bills Image Dual...